AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LANZL, L. H.
Right arrow Articles by AHRENS, T. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by LANZL, L. H.
Right arrow Articles by AHRENS, T. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 103, 863-870, Copyright © 1968 by American Roentgen Ray Society


DEPTH DOSE STUDIES IN ELECTRON BEAM THERAPY

EFFECTS ON ANAGEN MOUSE HAIRS

LAWRENCE H. LANZL PH.D.1, FREDERICK D. MALKINSON M.D., D.M.D. 2, and THOMAS J. AHRENS 3

1 From the Department of Radiology, and the Argonne Cancer Research Hospital, The University of Chicago, Chicago, Illinois
2 From the Department of Medicine (Dermatology), The University of Chicago, Chicago, Illinois
3 The Argonne Cancer Research Hospital, The University of Chicago, Chicago, Illinois

Detailed physical and biologic depth dose studies for a 20 mev. scanning electron beam are reported to further elucidate the clinical impression of "skin sparing" effect observed when electron beams are used for cancer therapy. The biologic dosimeter used was the damaging effect on anagen mouse hair by electron irradiation. There is substantial agreement of the "surface-to-plateau" dose ratio between the physical and biologic dosimeters utilized here. Even though the linear energy transfer (LET) cannot be expected to be identical at the surface as compared with the depth, this difference has not produced a significantly different RBE at the two positions for the biologic indicator used.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1968 by the American Roentgen Ray Society.