AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by MILLER, C. E.
Right arrow Articles by FINKEL, A. J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by MILLER, C. E.
Right arrow Articles by FINKEL, A. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 103, 871-880, Copyright © 1968 by American Roentgen Ray Society


RADIUM RETENTION IN MAN AFTER MULTIPLE INJECTIONS

THE POWER FUNCTION RE-EVALUATED

CHARLES E. MILLER PH.D.1 and ASHER J. FINKEL M.D.1

1 From the Health Division, Argonne National Laboratory, Argonne, Illinois

The parameters proposed by Norris et al.12,13 for the power function, R = 0.54 t0.52, that has been widely employed as a description of the retention of radium in humans, have been recalculated. The new computation was based on a 33 year span of data collected on 8 patients who received radium by injection in 1931-1933, and who were studied by Norris and his colleagues in 1951-1953. In several cases the previously employed radium injection schedule was revised on the basis of information from original hospital records. The new analysis yielded average power functions of R = 0.30 t-0.44 for the complete series of 8 patients and R = 0.20 t-0.36 for the 5 patients whose injection schedules are more reliably known. The individually fitted power functions for the 8 patients ranged from R = 0.15 t-0.19 to R = 0.98 t-0.63. The retention of radium in humans after one year had elapsed since administration can be expressed as well by a single exponential term with a half-time of 14.98 years and an injected dose coefficient of 0.0246 as by the average power function. This single exponential term and the power function, R = 0.20 t-0.36, are equally satisfactory for estimating the total amount of radium that entered the bloodstream of these patients.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1968 by the American Roentgen Ray Society.