AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wallace, M.
Right arrow Articles by Charnsangavej, C
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wallace, M.
Right arrow Articles by Charnsangavej, C
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 147, Issue 6, 1247-1250
Copyright © 1986 by American Roentgen Ray Society


Articles

Inferior vena caval stent filter

MJ Wallace, K Ogawa, K Wright, CH Carrasco, W Richli, and C Charnsangavej

New inferior vena caval filters for percutaneous placement were made by attaching filter wires similar to those in the bird's nest inferior vena caval filter onto expandable metallic stents. These stents formed a base on which to anchor the filter to the wall of the inferior vena cava. The stent filter can be introduced through a 12- to 13-French catheter sheath system. The system was successfully tested in 13 dogs.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1986 by the American Roentgen Ray Society.