AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Acheson, M.
Right arrow Articles by Stimac, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Acheson, M.
Right arrow Articles by Stimac, G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 148, Issue 6, 1179-1185
Copyright © 1987 by American Roentgen Ray Society


Articles

High-resolution CT scanning in the evaluation of cervical spine fractures: comparison with plain film examinations

MB Acheson, RR Livingston, ML Richardson, and GK Stimac

Forty-nine patients with cervical spine fractures were identified among 160 patients who underwent CT of the cervical spine for blunt trauma. Although there was a high index of suspicion on the plain film interpretation, as well as a large percentage of false positives, many fractures were found on CT that were not suggested, even in retrospect, on the plain radiographs. Of the 136 fractures ultimately identified in these patients, CT detected 135 (99%) while only 64 (47%) were seen or suspected on the initial screening radiographs. At first glance, this might appear to discredit the plain films as a screening device. However, most of these "occult" fractures occurred in vertebrae that had been identified as probably fractured in other parts, for example, pedicle fractures found in vertebrae initially suspected of harboring only a vertebral body fracture. Most of the remainder of the uncovered fractures were in vertebrae immediately adjacent to ones that were initially identified as fractured. Indeed, of the 49 patients with fractures, only one had an adequately exposed and positioned plain film that was completely normal. The ability of CT to determine quickly and confidently the presence or absence of cervical fractures and to define the position of fragments in relation to the spinal canal is of considerable value in the medical and nursing management of the seriously traumatized patient. For example, when a fracture is seen or suspected on conventional films, a limited CT examination of the area is recommended. Plain films should be used to guide the CT examination so that an intact vertebra above and below the lesion is included. If an adequately exposed and positioned plain film series of the cervical spine is normal, it is unlikely that CT will reveal a fracture. While conventional radiographs fail to detect a surprising number of fractures, they retain their value as a screening tool and as a guide to selective CT imaging.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
I. K. Moppett
Traumatic brain injury: assessment, resuscitation and early management
Br. J. Anaesth., July 1, 2007; 99(1): 18 - 31.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
P. T. McCulloch, J. France, D. L. Jones, W. Krantz, T.-P. Nguyen, C. Chambers, J. Dorchak, and P. Mucha
Helical Computed Tomography Alone Compared with Plain Radiographs with Adjunct Computed Tomography to Evaluate the Cervical Spine After High-Energy Trauma
J. Bone Joint Surg. Am., November 1, 2005; 87(11): 2388 - 2394.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
J. MINIGH
Imaging Sports-related Injuries
Radiol. Technol., November 1, 2005; 77(2): 121 - 138.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. J. Hogan, S. E. Mirvis, K. Shanmuganathan, and T. M. Scalea
Exclusion of Unstable Cervical Spine Injury in Obtunded Patients with Blunt Trauma: Is MR Imaging Needed when Multi-Detector Row CT Findings Are Normal?
Radiology, October 1, 2005; 237(1): 106 - 113.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. D. Bub, C. C. Blackmore, F. A. Mann, and F. M. Lomoschitz
Cervical Spine Fractures in Patients 65 Years and Older: A Clinical Prediction Rule for Blunt Trauma
Radiology, January 1, 2005; 234(1): 143 - 149.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
L. M. E. Jelly, D. R. Evans, M. J. Easty, T. J. Coats, and O. Chan
Radiography versus Spiral CT in the Evaluation of Cervicothoracic Junction Injuries in Polytrauma Patients Who Have Undergone Intubation
RadioGraphics, October 1, 2000; 20(90001): 251S - 259.
[Abstract] [Full Text]


Home page
RadiologyHome page
C. C. Blackmore, S. D. Ramsey, F. A. Mann, and R. A. Deyo
Cervical Spine Screening with CT in Trauma Patients: A Cost-effectiveness Analysis
Radiology, July 1, 1999; 212(1): 117 - 125.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1987 by the American Roentgen Ray Society.