AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shellock, F.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shellock, F.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
American Journal of Roentgenology, Vol 151, Issue 4, 811-814
Copyright © 1988 by American Roentgen Ray Society


Articles

MR imaging of metallic implants and materials: a compilation of the literature

FG Shellock

Department of Medicine, Cedars-Sinai Medical Center, Los Angeles, CA 90048.

Ferromagnetic metallic implants and materials are regarded as contraindications for MR imaging because of the potential risks associated with their movement or displacement. To date, 14 published articles have evaluated the ferromagnetic qualities of 127 different metallic implants and other materials, including aneurysm and hemostatic clips (32); dental implants and materials (five); intravascular coils, filters, and stents (13); ear implants (14); prosthetic heart valves (29); orthopedic implants and materials (eight); penile implants (nine); and miscellaneous metallic implants and materials (17). All of these materials were evaluated by measuring the deflection forces induced by static magnetic fields at strengths ranging from 0.147 to 4.7 T. This article is a compilation of the results of these studies; it lists all 127 of the materials tested, indicates whether they were found to be deflected by the static magnetic fields, and gives the highest static magnetic field strength at which they were evaluated. Of the metallic implants tested, 66 were nonferromagnetic, and 29 exhibited only minimal deflection relative to their in vivo applications (i.e., the deflection forces were thought to be insufficient to move or dislodge the implant or material in situ). The authors of these studies concluded that patients with these particular metallic implants or materials (95/127, 75%) can be examined safely by MR imaging with scanners having static magnetic field strengths up to and including those used for the specific evaluations. Patients with other ferromagnetic materials or implants may also undergo MR imaging safely; however, both careful consideration of the factors that influence the deflection of metallic implants and prudent clinical judgment are required before patients who have these objects are examined via MR imaging.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
PediatricsHome page
O. J. Muensterer
Temporary Removal of Navel Piercing Jewelry for Surgery and Imaging Studies
Pediatrics, September 1, 2004; 114(3): e384 - e386.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Hug, E. Nagel, A. Bornstedt, B. Schnackenburg, H. Oswald, and E. Fleck
Coronary Arterial Stents: Safety and Artifacts during MR Imaging
Radiology, September 1, 2000; 216(3): 781 - 787.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1988 by the American Roentgen Ray Society.