American Journal of Roentgenology, Vol 154, 185-190, Copyright © 1990 by American Roentgen Ray Society
ARTICLES |
JP Felmlee, JE Gray, ML Leetzow and JC Price
Department of Diagnostic Radiology, Mayo Clinic and Foundation, Rochester, MN 55905.
It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X- ray tube output, and equipment calibration are considered.
This article has been cited by other articles:
![]() |
E. Angel, C. V. Wellnitz, M. M. Goodsitt, N. Yaghmai, J. J. DeMarco, C. H. Cagnon, J. W. Sayre, D. D. Cody, D. M. Stevens, A. N. Primak, et al. Radiation Dose to the Fetus for Pregnant Patients Undergoing Multidetector CT Imaging: Monte Carlo Simulations Estimating Fetal Dose for a Range of Gestational Age and Patient Size Radiology, October 1, 2008; 249(1): 220 - 227. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. Jaffe, T. T. Yoshizumi, G. I. Toncheva, G. Nguyen, L. M. Hurwitz, and R. C. Nelson Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current Modulation Am. J. Roentgenol., April 1, 2008; 190(4): 860 - 864. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Huda and A. Vance Patient Radiation Doses from Adult and Pediatric CT Am. J. Roentgenol., February 1, 2007; 188(2): 540 - 546. [Abstract] [Full Text] [PDF] |
||||
![]() |
S Mori, K Nishizawa, M Ohno, and M Endo Conversion factor for CT dosimetry to assess patient dose using a 256-slice CT scanner Br. J. Radiol., November 1, 2006; 79(947): 888 - 892. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. M. Hurwitz, T. Yoshizumi, R. E. Reiman, P. C. Goodman, E. K. Paulson, D. P. Frush, G. Toncheva, G. Nguyen, and L. Barnes Radiation Dose to the Fetus from Body MDCT During Early Gestation. Am. J. Roentgenol., March 1, 2006; 186(3): 871 - 876. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Nickoloff and P. O. Alderson Radiation Exposures to Patients from CT: Reality, Public Perception, and Policy Am. J. Roentgenol., August 1, 2001; 177(2): 285 - 287. [Full Text] [PDF] |
||||