AJR Not a Member? Click to Join ARRS!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Evens, R. G.
Right arrow Articles by Evens, R. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Evens, R. G.
Right arrow Articles by Evens, R. G., Jr
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 157, 603-607, Copyright © 1991 by American Roentgen Ray Society


ARTICLES

Analysis of economics and use of MR imaging units in the United States in 1990

RG Evens and RG Evens Jr
Mallinckrodt Institute of Radiology, Washington University, St. Louis, MO 63110.

Personnel from the 72 facilities with the most experience in MR imaging were surveyed, and 45 questionnaires were returned with data to study the economics and use of MR imaging facilities. The data from 1990 were compared with results of studies done in 1985 and 1987. The facilities studied were highly selected, and the data and conclusions are unlikely to be representative of all MR facilities currently operational in the United States. The "typical" MR unit operated about 66 hr per week and imaged 68 patients. Most procedures were examinations of the head and spine (73%), with examinations of bone and joint increasing in frequency (17%). Scheduling delays for both inpatients and outpatients have decreased since 1987, indicating that clinical demand is being met by MR facilities. The global (technical plus professional) charge for an examination was approximately $950, and the charge for IV contrast material was an additional $200. IV contrast material was used in approximately 40% of head and 20% of spine studies. The typical MR units in 1990 was used to examine more than 3000 patients per year at a charge of approximately $750 each for the technical component. Technical billings for each unit were approximately $2.3 million, and net revenues were almost $1.9 million. We estimate the annual operating cost of an MR unit in 1990 was $1.3 million, so the typical MR unit had an annual net profit of approximately $500,000. This is a considerable improvement from the economic position in 1985, when each MR unit was losing approximately $400,000 annually. We conclude that experienced MR imaging facilities are now profitable owing to increased efficiency and continually rising charges. We suggest the economic historical pattern demonstrated by MR imaging (large losses initially followed by profitability within several years owing to increased efficiency and higher charges) is a typical pattern for many new technologies with the current medical payment system in the United States.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
ANN INTERN MEDHome page
D. G.W. Fraser, A. R. Moody, P. S. Morgan, A. L. Martel, and I. Davidson
Diagnosis of Lower-Limb Deep Venous Thrombosis: A Prospective Blinded Study of Magnetic Resonance Direct Thrombus Imaging
Ann Intern Med, January 15, 2002; 136(2): 89 - 98.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
C. Landrigan
Preventable Deaths and Injuries during Magnetic Resonance Imaging
N. Engl. J. Med., September 27, 2001; 345(13): 1000 - 1001.
[Full Text] [PDF]


Home page
American Journal of Medical QualityHome page
H. R. Grable
Abnormal Findings on Magnetic Resonance Imaging in a Group of Motor Vehicle Accident Patients with Low Back Pain
American Journal of Medical Quality, December 1, 1993; 8(4): 194 - 196.
[Abstract] [PDF]


Home page
NEJMHome page
R. R. Edelman and S. Warach
Magnetic Resonance Imaging- Second of Two Parts
N. Engl. J. Med., March 18, 1993; 328(11): 785 - 791.
[Full Text]


Home page
RadiologyHome page
B. J. Livstone, L. Parker, and D. C. Levin
Trends in the Utilization of MR Angiography and Body MR Imaging in the U.S. Medicare Population: 1993-1998
Radiology, March 1, 2002; 222(3): 615 - 618.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1991 by the American Roentgen Ray Society.