AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dodd, G. D.
Right arrow Articles by Santaguida, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dodd, G. D., 3rd
Right arrow Articles by Santaguida, L. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 164, 1119-1124, Copyright © 1995 by American Roentgen Ray Society


ARTICLES

Detection of transjugular intrahepatic portosystemic shunt dysfunction: value of duplex Doppler sonography

GD Dodd 3rd, AB Zajko, PD Orons, MS Martin, LS Eichner and LA Santaguida
Department of Radiology, University of Pittsburgh Medical Center, PA 15238, USA.

OBJECTIVE. Recent reports have shown that a high percentage of patients with transjugular intrahepatic portosystemic shunts (TIPS) have postprocedural shunt complications, including thrombosis of the stent, stenosis of the stent, or stenosis of the hepatic vein draining the stent. We did a prospective study to determine the utility of Doppler sonography as a screening technique for the detection of these complications. SUBJECTS AND METHODS. From September 1991 to September 1992 we placed TIPS in 45 patients. After the procedure, patients were routinely evaluated with both Doppler sonography and angiography. The sonographic protocol consisted of insonation of the stent, portal vein, and hepatic vein to determine the presence of flow, peak velocity, and direction of flow. The angiograms were evaluated for stenoses of the stent or hepatic vein that caused an increase in the portosystemic pressure gradient greater than 15 mm Hg, increased intrahepatic portal venous filling, retrograde filling of the draining hepatic vein, or opacification of varices. The sonographic findings were statistically evaluated to determine if sonography could demonstrate the complications shown by angiography. RESULTS. Adequate follow-up was obtained in 29 of the 45 patients. Sixteen of the 29 patients had shunt complications that consisted of one stent thrombosis, three stent stenoses, nine hepatic vein stenoses, and three concomitant stenoses of the stent and hepatic vein. Flow was not detected by sonography in the stent of the patient with thrombosis. There was a significant difference (p = .003) between the temporal change in peak stent velocity in patients with stenoses versus those without. Use of a change (increase or decrease) in peak stent velocity greater than 50 cm/sec from the post-TIPS baseline sonogram as the diagnostic criterion for the detection of shunt stenoses resulted in a 93% sensitivity and 77% specificity. Five patients with stenosis had reversed flow in the draining hepatic vein. Only one patient with a stenosis had a peak stent velocity less than 50 cm/sec. CONCLUSION. Our results suggest that Doppler sonography is an excellent noninvasive screening technique for the detection of complications of TIPS. We have found a temporal change in peak stent velocity greater than 50 cm/sec to be a more sensitive sonographic sign of TIPS stenosis than the previously reported low-velocity parameters. Our experience suggests that nearly all complications of TIPS can be detected by using three criteria: (1) no flow for thrombosis, (2) a temporal change in peak stent velocity greater than 50 cm/sec for stent and/or hepatic vein stenosis, and (3) reversed flow in the hepatic vein draining the stent for hepatic vein and, rarely, stent stenosis.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Journal of Diagnostic Medical SonographyHome page
C. Owen and P. Meyers
Sonographic Evaluation of the Portal and Hepatic Systems
Journal of Diagnostic Medical Sonography, September 1, 2006; 22(5): 317 - 328.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Lake, M. Guimaraes, S. Ackerman, C. Hannegan, C. Schonholz, J. B. Selby, and R. Uflacker
Comparative Results of Doppler Sonography After TIPS Using Covered and Bare Stents.
Am. J. Roentgenol., April 1, 2006; 186(4): 1138 - 1143.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
E. G. Grant, L. L. Barr, J. Borgstede, G. A.W. Gooding, U. M. Hamper, B. S. Hertzberg, M. Horrow, R. A. Kane, F. Kremkau, J. W. Meilstrup, et al.
AIUM Standard for the Performance of an Ultrasound Examination of the Abdomen or Retroperitoneum
J. Ultrasound Med., October 1, 2002; 21(10): 1182 - 1187.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
A S Shaw, S M Ryan, R C Beese, S Norris, M Bowles, M Rela, and P S Sidhu
Liver transplantation
Imaging, August 1, 2002; 14(4): 314 - 328.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. G. Sheiman, T. Vrachliotis, D. P. Brophy, and B. J. Ransil
Transmitted Cardiac Pulsations as an Indicator of Transjugular Intrahepatic Portosystemic Shunt Function: Initial Observations
Radiology, July 1, 2002; 224(1): 225 - 230.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
J. Zizka, P. Elias, A. Krajina, A. Michl, M. Lojik, P. Ryska, J. Maskova, P. Hulek, V. Safka, T. Vanasek, et al.
Value of Doppler Sonography in Revealing Transjugular Intrahepatic Portosystemic Shunt Malfunction: A 5-Year Experience in 216 Patients
Am. J. Roentgenol., July 1, 2000; 175(1): 141 - 148.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. A. Kliewer, B. S. Hertzberg, J. P. Heneghan, P. V. Suhocki, D. H. Sheafor, P. A. Gannon Jr., and E. K. Paulson
Transjugular Intrahepatic Portosystemic Shunts (TIPS): Effects of Respiratory State and Patient Position on the Measurement of Doppler Velocities
Am. J. Roentgenol., July 1, 2000; 175(1): 149 - 152.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Chopra, G. D. Dodd III, K. N. Chintapalli, H. Rhim, C. E. Encarnacion, J. C. Palmaz, C. C. Esola, and A. A. Ghiatas
Transjugular Intrahepatic Portosystemic Shunt: Accuracy of Helical CT Angiography in the Detection of Shunt Abnormalities
Radiology, April 1, 2000; 215(1): 115 - 122.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Roentgen Ray Society.