|
|
||||||||
American Journal of Roentgenology, Vol 164, 1451-1455, Copyright © 1995 by American Roentgen Ray Society
ARTICLES |
WR Reinus, KL Shady, SA Mirowitz and WG Totty
Mallinckrodt Institute of Radiology, Jewish Hospital, St. Louis, MO 63110, USA.
OBJECTIVE. The purpose of this study was to compare the use of fat- saturated T2-weighted spin-echo MR imaging with that of conventional T2- weighted spin-echo MR imaging to detect full- and partial-thickness tears of the rotator cuff of the shoulder, using arthroscopy as the standard for the diagnosis. SUBJECTS AND METHODS. Forty-nine consecutive patients with shoulder pain who had both MR imaging and arthroscopy of their affected shoulders were studied. The study group consisted of 10 patients with full-thickness tears of the rotator cuff, 20 with partial-thickness tears of the rotator cuff, and 19 with intact rotator cuff tendons proved arthroscopically. All patients had T1- weighted, conventional T2-weighted, and fat-saturated T2-weighted MR images obtained in a plane slightly oblique to the coronal plane along the long axis of the supraspinous tendon. The images were divided into two sets, one including both T1-weighted and conventional T2-weighted images, the other including T1-weighted and fat-saturated T2-weighted images. Two musculoskeletal radiologists reviewed each set of MR images in a blinded fashion. The reviewers were asked to decide whether the rotator cuff showed a full-thickness tear, a partial-thickness tear, or no tear on each set of images. In the case of partial-thickness tears, the reviewers were asked to indicate which surface (bursal or joint) of the rotator cuff was affected. These data were correlated with the arthroscopic findings and with each other using McNemar and kappa analysis. RESULTS. Detection of full-thickness tears was excellent for both reviewers using either imaging technique. However, when the fat- saturated technique was used, the sensitivity increased significantly, from 80% to 100%. Detection of partial-thickness tears was poor with conventional spin-echo MR imaging (15%). Although significantly improved when fat saturation was used (35%), detection rates were still lower than rates reported in the literature. Identification of the torn surface of the rotator cuff was correct in 50% of cases in which partial-thickness tears were successfully identified. Fat saturation decreased the specificity of identification of both partial and full- thickness tears of the rotator cuff but significantly increased the specificity with which intact rotator cuffs were identified. CONCLUSION. Use of the fat-saturation technique improved detection of both full-thickness and partial-thickness tears of the rotator cuff on MR images compared with standard spin-echo imaging techniques. Despite this improvement, detection of partial-thickness tears was poor with both techniques. Furthermore, correct identification of which surface of the rotator cuff was torn in patients with partial tears was nearly random.
This article has been cited by other articles:
![]() |
E. E. Spencer Jr, W. R. Dunn, R. W. Wright, B. R. Wolf, K. P. Spindler, E. McCarty, C. B. Ma, G. Jones, M. Safran, G. B. Holloway, et al. Interobserver Agreement in the Classification of Rotator Cuff Tears Using Magnetic Resonance Imaging Am. J. Sports Med., January 1, 2008; 36(1): 99 - 103. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Farber, L. Fayad, T. Johnson, B. Cascio, M. Shindle, P. Neubauer, and A. J. Khanna Magnetic Resonance Imaging of the Shoulder. Current Techniques and Spectrum of Disease J. Bone Joint Surg. Am., December 1, 2006; 88(suppl_4): 64 - 79. [Full Text] [PDF] |
||||
![]() |
T. Herold, M. Bachthaler, O. W. Hamer, R. Hente, S. Feuerbach, C. Fellner, M. Strotzer, M. Lenhart, and C. Paetzel Indirect MR Arthrography of the Shoulder: Use of Abduction and External Rotation to Detect Full- and Partial-Thickness Tears of the Supraspinatus Tendon Radiology, July 1, 2006; 240(1): 152 - 160. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. B. Stetson, T. Phillips, and A. Deutsch The Use of Magnetic Resonance Arthrography to Detect Partial-Thickness Rotator Cuff Tears J. Bone Joint Surg. Am., December 1, 2005; 87(suppl_2): 81 - 88. [Full Text] [PDF] |
||||
![]() |
R. Kijowski, J. M. Farber, J. Medina, W. Morrison, J. Ying, and K. Buckwalter Comparison of Fat-Suppressed T2-Weighted Fast Spin-Echo Sequence and Modified STIR Sequence in the Evaluation of the Rotator Cuff Tendon Am. J. Roentgenol., August 1, 2005; 185(2): 371 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. A. Teefey, D. A. Rubin, W. D. Middleton, C. F. Hildebolt, R. A. Leibold, and K. Yamaguchi Detection and Quantification of Rotator Cuff Tears. Comparison of Ultrasonographic, Magnetic Resonance Imaging, and Arthroscopic Findings in Seventy-one Consecutive Cases J. Bone Joint Surg. Am., April 1, 2004; 86(4): 708 - 716. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. P. Wu, T. J. Dubinsky, and M. L. Richardson Association of Shoulder Sonographic Findings With Subsequent Surgical Treatment for Rotator Cuff Injury J. Ultrasound Med., February 1, 2003; 22(2): 155 - 161. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Miniaci, A. T. Mascia, D. C. Salonen, and E. J. Becker Magnetic Resonance Imaging of the Shoulder in Asymptomatic Professional Baseball Pitchers Am. J. Sports Med., January 1, 2002; 30(1): 66 - 73. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Spielmann, B. B. Forster, P. Kokan, R. H. Hawkins, and D. L. Janzen Shoulder after Rotator Cuff Repair: MR Imaging Findings in Asymptomatic Individuals-Initial Experience Radiology, December 1, 1999; 213(3): 705 - 708. [Abstract] [Full Text] |
||||
![]() |
C. J. Seibold, T. A. Mallisee, S. J. Erickson, M. D. Boynton, W. G. Raasch, and M. E. Timins Rotator Cuff: Evaluation with US and MR Imaging RadioGraphics, May 1, 1999; 19(3): 685 - 705. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |