|
|
||||||||
American Journal of Roentgenology, Vol 164, 1495-1500, Copyright © 1995 by American Roentgen Ray Society
ARTICLES |
K Valji, JJ Bookstein, AC Roberts, SB Oglevie, C Pittman and MP O'Neill
Department of Radiology, University of California, San Diego, Medical Center 92103, USA.
OBJECTIVE. Pulse-spray pharmacomechanical thrombolysis is an evolving method for the treatment of vascular occlusions in which a highly concentrated fibrinolytic agent is injected as a high-pressure spray directly into thrombus. The purpose of this retrospective study was to analyze our long-term experience with this technique for the treatment of clotted hemodialysis grafts and to compare the efficacy and safety of the original and current methods. SUBJECTS AND METHODS. Over 6 years, 284 cases of dialysis graft thrombosis were considered suitable for treatment with pulse-spray thrombolysis. The original technique involved the injection of highly concentrated urokinase directly into a clot through two crisscross catheters with multiple side holes. The current technique includes early fragmentation of residual clot with a balloon catheter, intrathrombic injection of heparin, mechanical treatment of a lysis-resistant clot at the arterial anastomosis, and routine administration of aspirin. After thrombolysis, underlying obstructions were treated with balloon angioplasty, atherectomy, or stents. The technical success, immediate clinical success, and frequency of complications for the entire population were analyzed. In addition, the results for 36 cases treated with the original technique were compared with the results for 37 recent cases treated with the current technique. RESULTS. Of 284 cases considered suitable for treatment, thrombolysis was not done in eight cases because the venous anastomosis could not be crossed. Thrombolysis was discontinued in two cases because of extravasation of contrast material. The technical success for all grafts considered for treatment was 96%; 92% of treated grafts remained patent for at least 24 hr. Major complications occurred in 1% of cases, and minor complications occurred in 9% of cases. The clinical efficacies of the original and current techniques were 86% and 92%, respectively. The mean thrombolytic agent infusion time was reduced from 44 +/- 20 min to 23 +/- 13 min (p < .001). The overall procedure time for the recently treated subgroup was 67 +/- 26 min. There was no significant difference in the frequencies of major and minor complications between the treatment subgroups. CONCLUSION. Pulse- spray pharmacomechanical thrombolysis is a reliable, rapid, and safe method for recanalization of occluded dialysis grafts. The current technique has been proven as safe and effective as the original technique but offers the advantage of a significant reduction in the time required for the infusion of thrombolytic agent.
This article has been cited by other articles:
![]() |
G. Nano, I. Dalainas, R. Casana, P. Bianchi, T. Lupattelli, G. Malacrida, and D. G. Tealdi Stent Explantation From an Arteriovenous Fistula for Hemodialysis: A Case Report Angiology, October 1, 2006; 57(5): 647 - 649. [Abstract] [PDF] |
||||
![]() |
H. E. Rodriguez, L. Leon, P. Schalch, N. Labropoulos, M. Borge, and P. G. Kalman Arteriovenous Access: Managing Common Problems Perspectives in Vascular Surgery and Endovascular Therapy, June 1, 2005; 17(2): 155 - 166. [Abstract] [PDF] |
||||
![]() |
H.-B. Pan, H.-L. Liang, Y.-H. Lin, H.-M. Chung, T.-H. Wu, C.-Y. Chen, H.-C. Fang, C. K.-H. Chen, P.-H. Lai, and C.-F. Yang Metallic Stent Placement for Treating Peripheral Outflow Lesions in Native Arteriovenous Fistula Hemodialysis Patients After Insufficient Balloon Dilatation Am. J. Roentgenol., February 1, 2005; 184(2): 403 - 409. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Turmel-Rodrigues Stenosis and thrombosis in haemodialysis fistulae and grafts: the radiologist's point of view Nephrol. Dial. Transplant., February 1, 2004; 19(2): 306 - 308. [Full Text] [PDF] |
||||
![]() |
S. G. Cooper Pulse-Spray Thrombolysis of Thrombosed Hemodialysis Grafts with Tissue Plasminogen Activator Am. J. Roentgenol., April 1, 2003; 180(4): 1063 - 1066. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. B. Strauss, B. N. Delman, and A. Maitem A Rapid Low-Cost Uncrossed Sheath Method for Clearing Thrombosed Hemodialysis Grafts Am. J. Roentgenol., August 1, 2001; 177(2): 317 - 318. [Full Text] [PDF] |
||||
![]() |
H. I. Manninen, E. T. Kaukanen, R. Ikäheimo, P. Karhapää, T. Lahtinen, P. Matsi, and E. Lampainen Brachial Arterial Access: Endovascular Treatment of Failing Brescia-Cimino Hemodialysis Fistulas--Initial Success and Long-Term Results Radiology, March 1, 2001; 218(3): 711 - 718. [Abstract] [Full Text] |
||||
![]() |
K. H. Barth, M. R. Gosnell, A. M. Palestrant, L. G. Martin, J. B. Siegel, T. A. S. Matalon, S. C. Goodwin, P. A. Neese, T. L. Swan, and R. Uflacker Hydrodynamic Thrombectomy System versus Pulse-Spray Thrombolysis for Thrombosed Hemodialysis Grafts: A Multicenter Prospective Randomized Comparison Radiology, December 1, 2000; 217(3): 678 - 684. [Abstract] [Full Text] |
||||
![]() |
S. P. Murray, T. B. Kinney, K. Valji, A. C. Roberts, S. C. Rose, and S. B. Oglevie Early Rethrombosis of Clotted Hemodialysis Grafts: Graft Salvage Achieved with an Aggressive Approach Am. J. Roentgenol., August 1, 2000; 175(2): 529 - 532. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. T. Sofocleous, S. G. Cooper, I. Schur, R. I. Patel, A. Iqbal, and S. Walker Retrospective Comparison of the Amplatz Thrombectomy Device with Modified Pulse-Spray Pharmacomechanical Thrombolysis in the Treatment of Thrombosed Hemodialysis Access Grafts Radiology, November 1, 1999; 213(2): 561 - 567. [Abstract] [Full Text] |
||||
![]() |
B. L. Dolmatch, F. Casteneda, T. O. McNamara, G. Zemel, M. Lieber, and A. H. Cragg Synthetic Dialysis Shunts: Thrombolysis with the Cragg Thrombolytic Brush Catheter Radiology, October 1, 1999; 213(1): 180 - 184. [Abstract] [Full Text] |
||||
![]() |
S. M Bravo, R. D Reinhart, and M. F Meyerovitz Percutaneous venous interventions Vascular Medicine, February 1, 1998; 3(1): 61 - 66. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |