AJR Get Involved! Great Benefits! Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kimme-Smith, C.
Right arrow Articles by Johnson, S. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kimme-Smith, C.
Right arrow Articles by Johnson, S. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 165, 269-273, Copyright © 1995 by American Roentgen Ray Society


ARTICLES

Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom

C Kimme-Smith, DR Aberle, JW Sayre, EM Hart, SM Greaves, K Brown, DA Young, MD Deseran, T Johnson and SL Johnson
Department of Radiological Sciences, University of California at Los Angeles School of Medicine 90095-1721, USA.

OBJECTIVE. Radiographic exposure has been thought to have little impact on the diagnostic quality of chest computed radiography because of automatic digital control of global optical density. The objectives of this study were to compare images obtained with two different exposures in computed radiography with conventional and asymmetric screen-film images of the chest for the detection of simulated lung nodules by use of receiver operating characteristic analysis and to relate differences in observer performance to parameters of image noise measured for each receptor condition. MATERIALS AND METHODS. At 110 kVp (fixed), exposures for the two screen-film systems were those necessary to achieve adequate optical densities over the lung and mediastinal regions of an anthropomorphic phantom. The two exposures used for the computed radiographs corresponded to the exposure used for the conventional chest screen-film system and an exposure 22% lower. An anthropomorphic phantom constructed of materials matched to the muscle, lung, and bone attenuation of a muscular adult man was used. Soft- tissue-equivalent plastic nodules of various sizes were secured at multiple sites on the phantom to simulate lung nodules. The chest phantom was imaged in 50 configurations with a total of 70 superimposed nodules. The perceptual performances of five radiologists were compared by use of receiver operating characteristic analysis. The signal-to- noise ratio in the mediastinum and the coefficient of variation of noise were measured for all four image conditions by use of a step wedge technique to provide an explanation for differences in diagnostic accuracy. RESULTS. We found no significant differences in the detection of lung nodules between the two screen-film systems or between the conventional screen-film images and the standard-exposure computed radiographs. However, there was a significant decrease in nodule detection on computed radiographs obtained at a reduced exposure; this result was associated with a 21% decrease in the signal-to-noise ratio. CONCLUSION. Our results show that underexposure of computed radiographs decreases the detection of low-contrast objects such as lung nodules. Although consistent global optical density on computed radiographs is achieved over a wide range of exposures, the alterations in signal-to- noise ratio that result from underexposure can reduce the diagnostic quality of computed radiographs.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
radtechHome page
A. BRINDHABAN and K. AL KHALIFAH
Radiation Dose in Pelvic Imaging
Radiol. Technol., September 1, 2005; 77(1): 32 - 40.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. M. Bernhardt, D. Otto, G. Reichel, K. Ludwig, S. Seifert, S. Kropf, and U. Rapp-Bernhardt
Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based Radiography
Radiology, November 1, 1999; 213(2): 445 - 454.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Roentgen Ray Society.