|
|
||||||||
American Journal of Roentgenology, Vol 165, 535-540, Copyright © 1995 by American Roentgen Ray Society
ARTICLES |
HP van Heesewijk, U Neitzel, Y van der Graaf, JC de Valois and MA Feldberg
Department of Diagnostic Radiology, St. Antonius Hospital, Utrecht, The Netherlands.
OBJECTIVE. The purpose of this study was to compare a new digital chest radiography system that uses amorphous selenium as the X-ray detector with conventional radiography for the visualization of various anatomic regions of the chest as a first phase of testing image quality. MATERIALS AND METHODS. Six observers analyzed pairs of posteroanterior chest radiographs of 40 patients. One radiograph in each pair was obtained with a conventional chest film changer, and the other was obtained with the digital selenium chest radiography system. Each observer rated the visibility and the radiographic quality of 12 different anatomic regions. RESULTS. The observers rated visualization obtained with the digital system as better than that obtained with the conventional system in four regions (right lower lobe, upper lobes, ribs, and soft tissue), as better than or equal to that obtained with the conventional system in four regions (retrocardiac, retrodiaphragmatic, hilum, and upper mediastinum), and as equal to that obtained with the conventional system in four regions (horizontal fissure, carina, azygoesophageal recess, and thoracic spine). Some observers had a strong preference for the digital images, whereas others showed no preference. The conventional system was not ranked high for any region (2880 observations, p < .01, sign test). CONCLUSION. The digital selenium chest radiography system performs well in a clinical setting, providing visualization of anatomic structures that is better than or at least equal to that provided by standard screen-film images.
This article has been cited by other articles:
![]() |
M. Ganten, B. Radeleff, A. Kampschulte, M. D. Daniels, G. W. Kauffmann, and J. Hansmann Comparing Image Quality of Flat-Panel Chest Radiography with Storage Phosphor Radiography and Film-Screen Radiography Am. J. Roentgenol., July 1, 2003; 181(1): 171 - 176. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. S. Kim, J.-G. Im, J. M. Goo, K. H. Lee, Y.-J. Lee, S. H. Kim, and S. Kim Detection of Pulmonary Edema in Pigs: Storage Phosphor versus Amorphous Selenium-based Flat-Panel-Detector Radiography Radiology, June 1, 2002; 223(3): 695 - 701. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Zahringer, B. Krug, K.-F. Kamm, G. Wassmer, M. Hellmich, G. Winnekendonk, J. Andermahr, A. Go{beta}mann, and K. J. Lackner Detection of Porcine Bone Lesions and Fissures: Comparing Digital Selenium, Digital Luminescence, and Analog Film-Screen Radiography Am. J. Roentgenol., December 1, 2001; 177(6): 1397 - 1403. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Awai, M. Komi, and S. Hori Selenium-Based Digital Radiography Versus High-Resolution Storage Phosphor Radiography in the Detection of Solitary Pulmonary Nodules Without Calcification: Receiver Operating Characteristic Curve Analysis Am. J. Roentgenol., November 1, 2001; 177(5): 1141 - 1144. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Goo, J.-G. Im, J. H. Kim, J. B. Seo, T. S. Kim, S. J. Shine, and W. Lee Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System: Comparison of Soft-Copy Images Am. J. Roentgenol., October 1, 2000; 175(4): 1013 - 1018. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. P. Frush, L. F. Donnelly, and H. G. Chotas Contemporary Pediatric Thoracic Imaging Am. J. Roentgenol., September 1, 2000; 175(3): 841 - 851. [Full Text] [PDF] |
||||
![]() |
K. Ludwig, T. M. Link, M. Fiebich, B. Renger, S. Diederich, M. Oelerich, H. Lenzen, and W. Heindel Selenium-based Digital Radiography in the Detection of Bone Lesions: Preliminary Experience with Experimentally Created Defects Radiology, July 1, 2000; 216(1): 220 - 224. [Abstract] [Full Text] |
||||
![]() |
R. V. Kaczmarek, B. J. Conway, R. O. Slayton, and O. H. Suleiman Results of a Nationwide Survey of Chest Radiography: Comparison with Results of a Previous Study Radiology, June 1, 2000; 215(3): 891 - 896. [Abstract] [Full Text] |
||||
![]() |
M. Garmer, S. P. Hennigs, H. J. Jager, F. Schrick, T. van de Loo, A. Jacobs, A. Hanusch, A. Christmann, and K. Mathias Digital Radiography Versus Conventional Radiography in Chest Imaging: Diagnostic Performance of a Large-Area Silicon Flat-Panel Detector in a Clinical CT-Controlled Study Am. J. Roentgenol., January 1, 2000; 174(1): 75 - 80. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Bernhardt, D. Otto, G. Reichel, K. Ludwig, S. Seifert, S. Kropf, and U. Rapp-Bernhardt Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based Radiography Radiology, November 1, 1999; 213(2): 445 - 454. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |