AJR AJR Reprints & E-prints Available. Order Today!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dodd, G. D.
Right arrow Articles by Santiguida, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dodd, G. D., 3rd
Right arrow Articles by Santiguida, L. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 165, 573-577, Copyright © 1995 by American Roentgen Ray Society


ARTICLES

Portal vein thrombosis in patients with cirrhosis: does sonographic detection of intrathrombus flow allow differentiation of benign and malignant thrombus?

GD Dodd 3rd, DS Memel, RL Baron, L Eichner and LA Santiguida
University of Pittsburgh Medical Center, Department of Radiology, PA 15213, USA.

OBJECTIVE. The objective of our study was to determine if the detection by Doppler sonography of blood flow in portal vein thrombi occurring in patients with cirrhosis could be used to distinguish benign from malignant portal vein thrombi. SUBJECTS AND METHODS. Color and duplex Doppler sonographic examinations were performed in 47 patients with proven cirrhosis and portal vein thrombi. The examinations were directed at the detection of continuous or pulsatile flow within the portal vein thrombi. The nature of the portal vein thrombi was proven histologically in 27 patients and by CT findings and clinical history in 20 patients. The frequency, type, and direction of portal vein thrombus flow was evaluated to determine if there was any correlation with the benign or malignant nature of the portal vein thrombi. RESULTS. Of the 47 patients, 26 had malignant portal vein thrombi and 21 had benign portal vein thrombi. Blood flow was detected in 22 of the malignant and in 15 of the benign portal vein thrombi. The blood flow was pulsatile in 16 malignant and three benign portal vein thrombi and continuous in six malignant and 12 benign portal vein thrombi. The direction of the pulsatile flow in the malignant portal vein thrombi was predominantly (13/16) hepatofugal. All continuous flow in both benign and malignant portal vein thrombi was hepatopetal. The detection of pulsatile flow in portal vein thrombi yielded a 62% sensitivity and 95% specificity for the diagnosis of malignant portal vein thrombus. CONCLUSION. The detection by Doppler sonography of pulsatile flow in portal vein thrombi occurring in patients with cirrhosis is a moderately sensitive but highly specific sign for the diagnosis of malignant portal vein thrombus. However, continuous flow can be detected in benign and malignant portal vein thrombus and is thus not useful in differentiating between the two.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
J. M. Willatt, H. K. Hussain, S. Adusumilli, and J. A. Marrero
MR Imaging of Hepatocellular Carcinoma in the Cirrhotic Liver: Challenges and Controversies
Radiology, May 1, 2008; 247(2): 311 - 330.
[Abstract] [Full Text] [PDF]


Home page
Journal of Diagnostic Medical SonographyHome page
C. Owen and P. Meyers
Sonographic Evaluation of the Portal and Hepatic Systems
Journal of Diagnostic Medical Sonography, September 1, 2006; 22(5): 317 - 328.
[Abstract] [PDF]


Home page
J Ultrasound MedHome page
N. Ueno, H. Kawamura, H. Takahashi, N. Fujisawa, M. Yoneda, H. Kirikoshi, T. Sakaguchi, S. Saito, and S. Togo
Characterization of portal vein thrombus with the use of contrast-enhanced sonography.
J. Ultrasound Med., September 1, 2006; 25(9): 1147 - 1152.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Rossi, L. Rosa, V. Ravetta, A. Cascina, P. Quaretti, A. Azzaretti, P. Scagnelli, C. Tinelli, P. Dionigi, and F. Calliada
Contrast-enhanced versus conventional and color Doppler sonography for the detection of thrombosis of the portal and hepatic venous systems.
Am. J. Roentgenol., March 1, 2006; 186(3): 763 - 773.
[Abstract] [Full Text] [PDF]


Home page
ImagingHome page
A S Shaw, S M Ryan, R C Beese, S Norris, M Bowles, M Rela, and P S Sidhu
Liver transplantation
Imaging, August 1, 2002; 14(4): 314 - 328.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J.-H. Wang, T.-M. Chen, H.-D. Tung, C.-M. Lee, C.-S. Changchien, and S.-N. Lu
Color Doppler Sonography of Bile Duct Tumor Thrombi in Hepatocellular Carcinoma
J. Ultrasound Med., July 1, 2002; 21(7): 767 - 772.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1995 by the American Roentgen Ray Society.