AJR Custom publishing of AJR articles and ARRS Cat. Course
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cheung, A.
Right arrow Articles by Renner, J. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cheung, A.
Right arrow Articles by Renner, J. B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 168, 1305-1309, Copyright © 1997 by American Roentgen Ray Society


ARTICLES

The role of aspiration and contrast-enhanced arthrography in evaluating the uncemented hip arthroplasty

A Cheung, PF Lachiewicz and JB Renner
Department of Orthopaedics, University of North Carolina, Chapel Hill 27599-7055, USA.

OBJECTIVE: The purpose of this study was to determine the value of aspiration and contrast-enhanced arthrography in evaluating uncemented total hip arthroplasty components. A retrospective study was performed to determine the sensitivity, specificity, and accuracy of these procedures. MATERIALS AND METHODS: Preoperative aspiration of the hip joint and contrast-enhanced arthrography were performed by a skeletal radiologist in 33 hips with uncemented components before exploration or revision. In one patient, the hip aspiration yielded grossly purulent fluid and arthrography was not performed. Twenty-one uncemented acetabular components and 29 uncemented femoral components were evaluated by arthrography. The aspiration of the hip provided fluid for culture in 33 hips; in one hip, no fluid could be obtained. RESULTS: A preoperative diagnosis of infection based on growth on solid media was made in five hips (15%). An additional infection was determined to be present in the hip in which no fluid was obtained when purulent fluid was found at operation. On the basis of the operative findings, contrast-enhanced arthrography of the 21 acetabular components had a sensitivity of 50%, a specificity of 77%, and an accuracy of 68%. Arthrography of the 29 femoral components had a sensitivity of 63%, a specificity of 64%, and an accuracy of 63%. CONCLUSION: Aspiration of the hip joint before revision of uncemented hip arthroplasties was valuable because the diagnosis of infection was made preoperatively in five of six hips. However, contrast-enhanced arthrography was not valuable, with a low sensitivity and specificity for both uncemented acetabular and uncemented femoral components. Only a preoperative aspiration of the hip joint is recommended before revision of uncemented components.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J Bone Joint Surg BrHome page
O. P. P. Temmerman, P. G. H. M. Raijmakers, J. Berkhof, O. S. Hoekstra, G. J. J. Teule, and I. C. Heyligers
Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: A META-ANALYSIS
J Bone Joint Surg Br, June 1, 2005; 87-B(6): 781 - 785.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
O. P.P. Temmerman, P. G.H.M. Raijmakers, E. F.L. David, R. Pijpers, M. A. Molenaar, O. S. Hoekstra, J. Berkhof, R. A. Manoliu, G. J.J. Teule, and I. C. Heyligers
A Comparison of Radiographic and Scintigraphic Techniques to Assess Aseptic Loosening of the Acetabular Component in a Total Hip Replacement
J. Bone Joint Surg. Am., November 1, 2004; 86(11): 2456 - 2463.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Cyteval, V. Hamm, M. P. Sarrabere, F. M. Lopez, P. Maury, and P. Taourel
Painful Infection at the Site of Hip Prosthesis: CT Imaging
Radiology, August 1, 2002; 224(2): 477 - 483.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. M. White, J. K. Kim, M. Mehta, N. Merchant, M. E. Schweitzer, W. B. Morrison, C. R. Hutchison, and A. E. Gross
Complications of Total Hip Arthroplasty: MR Imaging-Initial Experience
Radiology, April 1, 2000; 215(1): 254 - 262.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Roentgen Ray Society.