AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sakuma, H.
Right arrow Articles by Higgins, C. B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sakuma, H.
Right arrow Articles by Higgins, C. B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 168, 1363-1367, Copyright © 1997 by American Roentgen Ray Society


ARTICLES

Quantification of coronary artery volume flow rate using fast velocity- encoded cine MR imaging

H Sakuma, M Saeed, K Takeda, MF Wendland, J Schwitter, DH Szolar, N Derugin, A Shimakawa, TK Foo and CB Higgins
Department of Radiology, University of California, San Francisco 94143- 0628, USA.

OBJECTIVE: Breath-hold velocity-encoded cine (VENC) MR imaging has been proposed as a method for measuring coronary blood flow. However, most studies have measured velocity rather than volume flow rate in the coronary arteries. The purpose of this study was to measure volume flow rate in the coronary artery of dogs using high-speed gradients and to compare MR flow measurements with those obtained with a sonographic flowmeter. MATERIALS AND METHODS: Fast VENC MR images were obtained with a high-speed-gradient 1.5-T MR system in seven anesthetized dogs before and after administration of dipyridamole. Images were acquired on double oblique planes perpendicular to the left anterior descending arteries with a slice thickness of 5 mm, a field of view of 20 x 10 cm, a velocity window of +/- 1 m/sec, an average imaging time of 21 sec, a TR/TE of 11/5, and a temporal resolution of 44 msec. RESULTS: Coronary flow measured with VENC MR imaging correlated well with flow measured by the flowmeter (r = .95, slope = 0.97, n = 88). Interobserver variability in measuring coronary flow volume was 8%. CONCLUSION: Fast VENC MR imaging with high-speed gradients can provide accurate quantification of volume flow rate in coronary arteries.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
L. P. Salm, S. E. Langerak, H. W. Vliegen, J. W. Jukema, J. J. Bax, A. H. Zwinderman, E. E. van der Wall, A. de Roos, and H. J. Lamb
Blood Flow in Coronary Artery Bypass Vein Grafts: Volume versus Velocity at Cardiovascular MR Imaging
Radiology, September 1, 2004; 232(3): 915 - 920.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Ishida, H. Sakuma, B. P. Cruz, T. Shimono, T. Tokui, I. Yada, K. Takeda, and C. B. Higgins
MR Flow Measurement in the Internal Mammary Artery-to-Coronary Artery Bypass Graft: Comparison with Graft Stenosis at Radiographic Angiography
Radiology, August 1, 2001; 220(2): 441 - 447.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. E. Langerak, P. Kunz, H. W. Vliegen, H. J. Lamb, J. W. Jukema, E. E. van der Wall, and A. de Roos
Improved MR Flow Mapping in Coronary Artery Bypass Grafts during Adenosine-induced Stress
Radiology, February 1, 2001; 218(2): 540 - 547.
[Abstract] [Full Text]


Home page
RadiologyHome page
G. K. Lund, M. F. Wendland, A. Shimakawa, H. Arheden, F. Ståhlberg, C. B. Higgins, and M. Saeed
Coronary Sinus Flow Measurement by Means of Velocity-encoded Cine MR Imaging: Validation by Using Flow Probes in Dogs
Radiology, November 1, 2000; 217(2): 487 - 493.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
H. Sakuma, J. W. Koskenvuo, P. Niemi, N. Kawada, J. O. Toikka, J. Knuuti, H. Laine, M. Saraste, M. Kormano, and J. J. Hartiala
Assessment of Coronary Flow Reserve Using Fast Velocity-Encoded Cine MR Imaging: Validation Study Using Positron Emission Tomography
Am. J. Roentgenol., October 1, 2000; 175(4): 1029 - 1033.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
J. Schwitter, T. DeMarco, S. Kneifel, G. K. von Schulthess, M. C. Jorg, H. Arheden, S. Ruhm, K. Stumpe, A. Buck, W. W. Parmley, et al.
Magnetic Resonance-Based Assessment of Global Coronary Flow and Flow Reserve and Its Relation to Left Ventricular Functional Parameters : A Comparison With Positron Emission Tomography
Circulation, June 13, 2000; 101(23): 2696 - 2702.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Kawada, H. Sakuma, T. Yamakado, K. Takeda, N. Isaka, T. Nakano, and C. B. Higgins
Hypertrophic Cardiomyopathy: MR Measurement of Coronary Blood Flow and Vasodilator Flow Reserve in Patients and Healthy Subjects
Radiology, April 1, 1999; 211(1): 129 - 135.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Roentgen Ray Society.