American Journal of Roentgenology, Vol 168, 1363-1367, Copyright © 1997 by American Roentgen Ray Society
ARTICLES |
H Sakuma, M Saeed, K Takeda, MF Wendland, J Schwitter, DH Szolar, N Derugin, A Shimakawa, TK Foo and CB Higgins
Department of Radiology, University of California, San Francisco 94143- 0628, USA.
OBJECTIVE: Breath-hold velocity-encoded cine (VENC) MR imaging has been proposed as a method for measuring coronary blood flow. However, most studies have measured velocity rather than volume flow rate in the coronary arteries. The purpose of this study was to measure volume flow rate in the coronary artery of dogs using high-speed gradients and to compare MR flow measurements with those obtained with a sonographic flowmeter. MATERIALS AND METHODS: Fast VENC MR images were obtained with a high-speed-gradient 1.5-T MR system in seven anesthetized dogs before and after administration of dipyridamole. Images were acquired on double oblique planes perpendicular to the left anterior descending arteries with a slice thickness of 5 mm, a field of view of 20 x 10 cm, a velocity window of +/- 1 m/sec, an average imaging time of 21 sec, a TR/TE of 11/5, and a temporal resolution of 44 msec. RESULTS: Coronary flow measured with VENC MR imaging correlated well with flow measured by the flowmeter (r = .95, slope = 0.97, n = 88). Interobserver variability in measuring coronary flow volume was 8%. CONCLUSION: Fast VENC MR imaging with high-speed gradients can provide accurate quantification of volume flow rate in coronary arteries.
This article has been cited by other articles:
![]() |
L. P. Salm, S. E. Langerak, H. W. Vliegen, J. W. Jukema, J. J. Bax, A. H. Zwinderman, E. E. van der Wall, A. de Roos, and H. J. Lamb Blood Flow in Coronary Artery Bypass Vein Grafts: Volume versus Velocity at Cardiovascular MR Imaging Radiology, September 1, 2004; 232(3): 915 - 920. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Ishida, H. Sakuma, B. P. Cruz, T. Shimono, T. Tokui, I. Yada, K. Takeda, and C. B. Higgins MR Flow Measurement in the Internal Mammary Artery-to-Coronary Artery Bypass Graft: Comparison with Graft Stenosis at Radiographic Angiography Radiology, August 1, 2001; 220(2): 441 - 447. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. E. Langerak, P. Kunz, H. W. Vliegen, H. J. Lamb, J. W. Jukema, E. E. van der Wall, and A. de Roos Improved MR Flow Mapping in Coronary Artery Bypass Grafts during Adenosine-induced Stress Radiology, February 1, 2001; 218(2): 540 - 547. [Abstract] [Full Text] |
||||
![]() |
G. K. Lund, M. F. Wendland, A. Shimakawa, H. Arheden, F. Ståhlberg, C. B. Higgins, and M. Saeed Coronary Sinus Flow Measurement by Means of Velocity-encoded Cine MR Imaging: Validation by Using Flow Probes in Dogs Radiology, November 1, 2000; 217(2): 487 - 493. [Abstract] [Full Text] |
||||
![]() |
H. Sakuma, J. W. Koskenvuo, P. Niemi, N. Kawada, J. O. Toikka, J. Knuuti, H. Laine, M. Saraste, M. Kormano, and J. J. Hartiala Assessment of Coronary Flow Reserve Using Fast Velocity-Encoded Cine MR Imaging: Validation Study Using Positron Emission Tomography Am. J. Roentgenol., October 1, 2000; 175(4): 1029 - 1033. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Schwitter, T. DeMarco, S. Kneifel, G. K. von Schulthess, M. C. Jorg, H. Arheden, S. Ruhm, K. Stumpe, A. Buck, W. W. Parmley, et al. Magnetic Resonance-Based Assessment of Global Coronary Flow and Flow Reserve and Its Relation to Left Ventricular Functional Parameters : A Comparison With Positron Emission Tomography Circulation, June 13, 2000; 101(23): 2696 - 2702. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Kawada, H. Sakuma, T. Yamakado, K. Takeda, N. Isaka, T. Nakano, and C. B. Higgins Hypertrophic Cardiomyopathy: MR Measurement of Coronary Blood Flow and Vasodilator Flow Reserve in Patients and Healthy Subjects Radiology, April 1, 1999; 211(1): 129 - 135. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |