AJR AJR Reprints & E-prints Available. Order Today!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Melhem, E. R.
Right arrow Articles by Eustace, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Melhem, E. R.
Right arrow Articles by Eustace, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 169, 859-862, Copyright © 1997 by American Roentgen Ray Society


ARTICLES

Fluid-attenuated inversion recovery MR imaging: identification of protein concentration thresholds for CSF hyperintensity

ER Melhem, H Jara and S Eustace
Department of Radiology, Boston University School of Medicine, Boston Medical Center, MA 02118, USA.

OBJECTIVE: Using human volunteers and phantoms emulating CSF, we analyzed the effects of varying protein concentration on the signal intensity of saline solution. Also, for different fluid-attenuated inversion recovery (FLAIR) sequences, we compared protein concentration thresholds above which the signal from these solutions becomes hyperintense to that from brain parenchyma. SUBJECTS AND METHODS: Nine albumin solutions of varying concentrations (3.9 mg/dl to 2500 mg/dl) were imaged using fast FLAIR MR sequences (TR, 6000 msec: inversion time, 1730 msec: echo train length, 20) at different effective TEs (110, 150, 200, and 250 signal-to-noise ratios from the different albumin solutions versus albumin concentration were generated and correlated with average signal-to-noise ratios from brain parenchyma and CSF. RESULTS: We saw a gradual increase in signal-to-noise ratios from the albumin solutions as a function of albumin concentration. As the effective TE increased, the point of intersection between the plots and the average signal-to-noise ratio from brain parenchyma occurred at lower albumin concentrations. CONCLUSION: FLAIR MR imaging is potentially useful to evaluate pathologic conditions that increase CSF protein concentration. Using phantoms and healthy volunteers, we defined a protein concentration threshold above which the signal from saline solutions becomes hyperintense to that from brain parenchyma. This threshold depends on the effective TE used in the FLAIR sequence and is 250 mg/dl for an effective TE of 110 msec, 125 mg/dl for 150 msec. 110 mg/dl for 200 msec, and 95 mg/dl for 250 msec.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
M. Tosaka, N. Sato, H. Fujimaki, Y. Tanaka, K. Kagoshima, A. Takahashi, N. Saito, and Y. Yoshimoto
Diffuse Pachymeningeal Hyperintensity and Subdural Effusion/Hematoma Detected by Fluid-Attenuated Inversion Recovery MR Imaging in Patients with Spontaneous Intracranial Hypotension
AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): 1164 - 1170.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R.A. Bhadelia, K.L. Tedesco, S. Hwang, S.H. Erbay, P.H. Lee, W. Shao, and C. Heilman
Increased Cochlear Fluid-Attenuated Inversion Recovery Signal in Patients with Vestibular Schwannoma
AJNR Am. J. Neuroradiol., April 1, 2008; 29(4): 720 - 723.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
J.M. Morris and G.M. Miller
Increased Signal in the Subarachnoid Space on Fluid-Attenuated Inversion Recovery Imaging Associated with the Clearance Dynamics of Gadolinium Chelate: A Potential Diagnostic Pitfall
AJNR Am. J. Neuroradiol., November 1, 2007; 28(10): 1964 - 1967.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. Cianfoni, M.G.M. Martin, J. Du, J.R. Hesselink, S.G. Imbesi, W.G. Bradley, and G.M. Bydder
Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary.
AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 843 - 849.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
Y. Anzai, M. Ishikawa, D. W. W. Shaw, A. Artru, V. Yarnykh, and K. R. Maravilla
Paramagnetic Effect of Supplemental Oxygen on CSF Hyperintensity on Fluid-Attenuated Inversion Recovery MR Images
AJNR Am. J. Neuroradiol., February 1, 2004; 25(2): 274 - 279.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Frigon, D. S. Jardine, E. Weinberger, S. R. Heckbert, and D. W. W. Shaw
Fraction of Inspired Oxygen in Relation to Cerebrospinal Fluid Hyperintensity on FLAIR MR Imaging of the Brain in Children and Young Adults Undergoing Anesthesia
Am. J. Roentgenol., September 1, 2002; 179(3): 791 - 796.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
H.-M. Wu, D. M. Yousem, H.-W. Chung, W.-Y. Guo, C.-Y. Chang, and C.-Y. Chen
Influence of Imaging Parameters on High-Intensity Cerebrospinal Fluid Artifacts in Fast-FLAIR MR Imaging
AJNR Am. J. Neuroradiol., March 1, 2002; 23(3): 393 - 399.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
A. T. Rai and J. P. Hogg
Persistence of Gadolinium in CSF: A Diagnostic Pitfall in Patients with End-stage Renal Disease
AJNR Am. J. Neuroradiol., August 1, 2001; 22(7): 1357 - 1361.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R. L. Wolf
Intraarterial Signal on Fluid-attenuated Inversion Recovery Images: A Measure of Hemodynamic Stress?
AJNR Am. J. Neuroradiol., June 1, 2001; 22(6): 1015 - 1017.
[Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. G. Filippi, A. M. Ulug, D. Lin, L. A. Heier, and R. D. Zimmerman
Hyperintense Signal Abnormality in Subarachnoid Spaces and Basal Cisterns on MR Images of Children Anesthetized with Propofol: New Fluid-attenuated Inversion Recovery Finding
AJNR Am. J. Neuroradiol., February 1, 2001; 22(2): 394 - 399.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Taoka, W. T. C. Yuh, M. L. White, J. P. Quets, J. E. Maley, and T. Ueda
Sulcal Hyperintensity on Fluid-Attenuated Inversion Recovery MR Images in Patients Without Apparent Cerebrospinal Fluid Abnormality
Am. J. Roentgenol., February 1, 2001; 176(2): 519 - 524.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. V. Deliganis, D. J. Fisher, A. M. Lam, and K. R. Maravilla
Cerebrospinal Fluid Signal Intensity Increase on FLAIR MR Images in Patients under General Anesthesia: The Role of Supplemental O2
Radiology, January 1, 2001; 218(1): 152 - 156.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
K. Noguchi, H. Seto, Y. Kamisaki, G. Tomizawa, S. Toyoshima, and N. Watanabe
Comparison of Fluid-attenuated Inversion-recovery MR Imaging with CT in a Simulated Model of Acute Subarachnoid Hemorrhage
AJNR Am. J. Neuroradiol., May 1, 2000; 21(5): 923 - 927.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
R. Bakshi, S. Kamran, P. R. Kinkel, V. E. Bates, L. L. Mechtler, V. Janardhan, S. L. Belani, and W. R. Kinkel
Fluid-Attenuated Inversion-Recovery MR Imaging in Acute and Subacute Cerebral Intraventricular Hemorrhage
AJNR Am. J. Neuroradiol., April 1, 1999; 20(4): 629 - 636.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Roentgen Ray Society.