American Journal of Roentgenology, Vol 170, 89-92, Copyright © 1998 by American Roentgen Ray Society
ARTICLES |
KA Goodman, RL Birdwell and DM Ikeda
Department of Radiology, Stanford University School of Medicine, CA 94305-5105, USA.
OBJECTIVE: The purpose of this study was to use information from an established patient tracking system to evaluate patient outcome and assess patient compliance with recommended follow-up after percutaneous breast core biopsy. MATERIALS AND METHODS: All breast core biopsies performed from January 1994 through February 14, 1996, that used stereotaxic or sonographic guidance were reviewed. Clinical, imaging, and pathologic findings were correlated with patient outcomes established by recommended surgical and nonsurgical follow-up. RESULTS: Of 160 core biopsies in 153 women, 30 biopsies were performed on the basis of clinical complaints. One hundred thirty lesions were detected by mammography or sonography or both. Of the 70 lesions recommended for surgical excision, 52 (74%) had documented surgical outcomes. Mammographic surveillance was recommended for 90 lesions, of which 10 (11%) had resolved at the time of this study, 49 (54%) were on track toward 3-year lesion stability, 21 (23%) were being followed up elsewhere, four (4%) were lost to physicians, and six (7%) were lost to follow-up for other reasons. CONCLUSION: Known compliance with follow- up recommendations among these 153 patients who underwent breast core biopsy was higher for patients receiving surgical recommendation (74%) than for patients receiving imaging surveillance recommendation (54%). Problems tracking patients were caused both by loss of patients to follow-up and by incomplete reporting from referring physicians.
This article has been cited by other articles:
![]() |
S. Raza, S. A. Chikarmane, S. S. Neilsen, L. M. Zorn, and R. L. Birdwell BI-RADS 3, 4, and 5 Lesions: Value of US in Management--Follow-up and Outcome Radiology, September 1, 2008; 248(3): 773 - 781. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Youk, E.-K. Kim, M. J. Kim, and K. K. Oh Sonographically Guided 14-Gauge Core Needle Biopsy of Breast Masses: A Review of 2,420 Cases with Long-Term Follow-Up Am. J. Roentgenol., January 1, 2008; 190(1): 202 - 207. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Youk, E.-K. Kim, M. J. Kim, J. Y. Lee, and K. K. Oh Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them RadioGraphics, January 1, 2007; 27(1): 79 - 94. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Berg Sonographically Depicted Breast Clustered Microcysts: Is Follow-Up Appropriate? Am. J. Roentgenol., October 1, 2005; 185(4): 952 - 959. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Liu, K. J. Mortele, and S. G. Silverman Incidental Extraurinary Findings at MDCT Urography in Patients with Hematuria: Prevalence and Impact on Imaging Costs Am. J. Roentgenol., October 1, 2005; 185(4): 1051 - 1056. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, N. Bracero, E. Morris, C. Thornton, and D. D. Dershaw MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy: Initial Clinical Experience Am. J. Roentgenol., July 1, 2005; 185(1): 183 - 193. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Kirshenbaum, T. Voruganti, C. Overbeeke, M. D. Kirshenbaum, P. Patel, G. Kaplan, V. Maker, C. August, and R. P. Cavallino Stereotactic Core Needle Biopsy of Nonpalpable Breast Lesions Using a Conventional Mammography Unit with an Add-On Device Am. J. Roentgenol., August 1, 2003; 181(2): 527 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. R. Margolin, J. W. T. Leung, R. P. Jacobs, and S. R. Denny Percutaneous Imaging-Guided Core Breast Biopsy: 5 Years' Experience in a Community Hospital Am. J. Roentgenol., September 1, 2001; 177(3): 559 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy? Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |