AJR AJR Integrative Imaging Dec 2008 articles
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mayo-Smith, W. W.
Right arrow Articles by McFarland, E. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mayo-Smith, W. W.
Right arrow Articles by McFarland, E. G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 170, 649-652, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

Pancreatic enhancement and pulse sequence analysis using low-dose mangafodipir trisodium

WW Mayo-Smith, W Schima, S Saini, GJ Slater and EG McFarland
Department of Radiology, Massachusetts General Hospital, Boston, MA, USA.

OBJECTIVE: The purpose of this study was to evaluate pancreatic enhancement with low-dose mangafodipir trisodium (5 mumol/kg) using three different T1-weighted pulse sequences. SUBJECTS AND METHODS: Fifteen patients, six of whom had proven focal pancreatic tumors, underwent T1-weighted gradient-recalled echo imaging, spin-echo imaging, and fat-suppressed spin-echo imaging before and 30 min after injection of 5 mumol/kg of mangafodipir trisodium. Region-of-interest measurements were obtained in the pancreas before and after contrast enhancement. Signal-to-noise ratios were calculated in all 15 patients. Contrast-to-noise ratios were calculated in the six patients with pancreatic tumors. RESULTS: The signal-to-noise ratios of the pancreas increased after injection of mangafodipir trisodium on all three T1- weighted pulse sequences (p < .001). Enhanced fat-suppressed sequences (29 +/- 7.7) and gradient-recalled echo sequences (29 +/- 9.6) had the highest signal-to-noise ratios. Contrast-to-noise ratios between normal pancreatic tissue and pancreatic tumor also increased after contrast administration (p < .05) and were highest on the fat-suppressed (-9.6 +/- 4.0) pulse sequence. CONCLUSION: Mangafodipir trisodium produced marked pancreatic enhancement at a dose of 5 mumol/kg for all three T1- weighted pulse sequences. The enhanced T1-weighted spin-echo fat- suppressed sequence showed the highest signal-to-noise and contrast-to- noise ratios.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.