AJR Custom publishing of AJR articles and ARRS Cat. Course
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Helbich, T. H.
Right arrow Articles by Mostbeck, G. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Helbich, T. H.
Right arrow Articles by Mostbeck, G. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 171, 59-63, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles

TH Helbich, M Rudas, A Haitel, PD Kohlberger, M Thurnher, M Gnant, P Wunderbaldinger, G Wolf and GH Mostbeck
Department of Radiology, University of Vienna, Austria.

OBJECTIVE: The purpose of our study was to compare the quantity and quality of tissue harvested from breast biopsy when using 14-, 16-, and 18-gauge "long-throw" needles. SUBJECTS AND METHODS: We performed a prospective randomized study in 64 patients with 66 breast lesions. Under stereotactic guidance, passes were made in random order with each of the three biopsy needles in each lesion. Samples were measured for tissue area and scored for their quality. All lesions, including benign and malignant lesions and lesions with and without microcalcifications, were analyzed. Findings of the biopsy samples were compared with the final diagnoses made at surgical excision. RESULTS: In all 66 lesions, 14-gauge biopsy needles obtained significantly larger specimens (14- gauge, 13.14 mm2; 16-gauge, 9.6 mm2; 18-gauge, 6.41 mm2; p < .05) and scored significantly better (14-gauge, 8.37; 16-gauge, 7.56; 18-gauge, 7.14; p < .016) than either of the smaller needles. The results for malignant and benign lesions and for lesions with and without microcalcifications were similar but not equal to the overall results. However, benign lesions and areas with microcalcifications seem to be more problematic for both smaller needles than for 14-gauge needles. CONCLUSION: Our results indicate that the quantity and quality of breast biopsy specimens depend on the needle size. Of the three needle sizes tested, only 14-gauge long-throw biopsy needles can be recommended for breast biopsy.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
J. S. Wu, J. D. Goldsmith, P. J. Horwich, S. K. Shetty, and M. G. Hochman
Bone and Soft-Tissue Lesions: What Factors Affect Diagnostic Yield of Image-guided Core-Needle Biopsy?
Radiology, September 1, 2008; 248(3): 962 - 970.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman
Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy
Radiology, September 1, 2004; 232(3): 897 - 903.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman
Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study
Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. K. Kuhl, N. Morakkabati, C. C. Leutner, A. Schmiedel, E. Wardelmann, and H. H. Schild
MR Imaging-guided Large-Core (14-Gauge) Needle Biopsy of Small Lesions Visible at Breast MR Imaging Alone
Radiology, July 1, 2001; 220(1): 31 - 39.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.