American Journal of Roentgenology, Vol 172, 683-687, Copyright © 1999 by American Roentgen Ray Society
ARTICLES |
LE Philpotts, NA Shaheen, D Carter, RC Lange and CH Lee
Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06520, USA.
OBJECTIVE: The 11-gauge vacuum suction probe is an alternative to the 14-gauge needle and automatic gun for performing stereotactic core needle biopsies. This study compares rebiopsy rates after stereotactic core needle biopsies that were performed with the two methods. The study also assesses the outcomes of those repeat biopsies. MATERIALS AND METHODS: Five hundred ninety-two stereotactic core needle biopsies using a 14-gauge needle and automatic gun and 354 using an 11-gauge vacuum suction probe were performed consecutively. Excluding malignancies, the number of cases requiring rebiopsy and the reasons for rebiopsy were determined for each group. The histologic diagnoses of the repeat biopsies were assessed. RESULTS: The rebiopsy rate was significantly lower with the 11-gauge vacuum suction probe (9.0%) than with the 14-gauge needle and automatic gun (14.9%) (p = .013). Significant reductions were found in cases of insufficient sampling (probe, 1.7%; needle, 4.4%; p = .042) and mammographic-pathologic discrepancy (probe, 0.8%; needle, 3.4%; p = .026). The rebiopsy rate for masses was 6.1% with the vacuum probe versus 10.7% with the 14- gauge needle (p = .12) and for calcifications was 11.6% with the vacuum probe versus 23.7% with the 14-gauge needle (p = .003). After rebiopsy, the percentage of cases in which malignancy was found was 18.5% with the vacuum probe versus 13.7% with the 14-gauge needle. On rebiopsy, the percentage of malignancies found in each category were atypical hyperplasia: probe 26.7%, needle 20.0%; insufficient sample: probe 0%, needle 9.5%; pathologist recommendation: probe 50.0%, needle 12.5%; and lobular carcinoma in situ: probe 0%, needle 100%. CONCLUSION: Use of the 11-gauge vacuum-assisted device significantly decreases but does not eliminate the need for rebiopsy after stereotactic core needle biopsy. The rebiopsy rate for calcifications was significantly reduced by using the vacuum suction probe rather than the 14-gauge needle; however, the rate for masses was reduced only slightly. On rebiopsy, malignancies were found in both groups.
This article has been cited by other articles:
![]() |
M. Jang, N. Cho, W. K. Moon, J. S. Park, M. H. Seong, and I. A. Park Underestimation of Atypical Ductal Hyperplasia at Sonographically Guided Core Biopsy of the Breast Am. J. Roentgenol., November 1, 2008; 191(5): 1347 - 1351. [Abstract] [Full Text] [PDF] |
||||
![]() |
E A Rakha and I O Ellis An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens J. Clin. Pathol., December 1, 2007; 60(12): 1300 - 1306. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-M. Lee, J. B. Kaplan, M. P. Murray, L. Bartella, E. A. Morris, S. Joo, D. D. Dershaw, and L. Liberman Imaging Histologic Discordance at MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., October 1, 2007; 189(4): 852 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Sohn, Z. Arthurs, G. Herbert, J. Keylock, J. Perry, M. Eckert, D. Fellabaum, D. Smith, and T. Brown Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle Ann. Surg. Oncol., September 1, 2007; 14(9): 2497 - 2501. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. H. Youk, E.-K. Kim, M. J. Kim, J. Y. Lee, and K. K. Oh Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them RadioGraphics, January 1, 2007; 27(1): 79 - 94. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman and J. Rodriguez-Soto Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome. Radiology, April 1, 2006; 239(1): 61 - 70. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. You, E.-K. Kim, J. Y. Kwak, M. J. Kim, K. K. Oh, B.-W. Park, and W. I. Yang Focal Fibrosis of the Breast Diagnosed by a Sonographically Guided Core Biopsy of Nonpalpable Lesions: Imaging Findings and Clinical Relevance J. Ultrasound Med., October 1, 2005; 24(10): 1377 - 1384. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis? Radiology, September 1, 2005; 236(3): 801 - 809. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Lehman, E. R. DePeri, S. Peacock, M. D. McDonough, W. B. DeMartini, and J. Shook Clinical Experience with MRI-Guided Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., June 1, 2005; 184(6): 1782 - 1787. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Lehman and T. Aikawa MR-guided Vacuum-assisted Breast Biopsy: Accuracy of Targeting and Success in Sampling in a Phantom Model Radiology, September 1, 2004; 232(3): 911 - 914. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. C. Foster, M. A. Helvie, N. E. Gregory, M. Rebner, A. V. Nees, and C. Paramagul Lobular Carcinoma in Situ or Atypical Lobular Hyperplasia at Core-Needle Biopsy: Is Excisional Biopsy Necessary? Radiology, June 1, 2004; 231(3): 813 - 819. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. S. Burnside, D. L. Rubin, R. D. Shachter, R. E. Sohlich, and E. A. Sickles A Probabilistic Expert System That Provides Automated Mammographic-Histologic Correlation: Initial Experience Am. J. Roentgenol., February 1, 2004; 182(2): 481 - 488. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Shousha Issues in the Interpretation of Breast Core Biopsies International Journal of Surgical Pathology, July 1, 2003; 11(3): 167 - 176. [Abstract] [PDF] |
||||
![]() |
L. E. Philpotts, R. J. Hooley, and C. H. Lee Comparison of Automated Versus Vacuum-Assisted Biopsy Methods for Sonographically Guided Core Biopsy of the Breast Am. J. Roentgenol., February 1, 2003; 180(2): 347 - 351. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Chen, B. G. Haffty, and C. H. Lee Local Recurrence of Breast Cancer after Breast Conservation Therapy in Patients Examined by Means of Stereotactic Core-Needle Biopsy Radiology, December 1, 2002; 225(3): 707 - 712. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Mainiero, I. F. Gareen, C. E. Bird, W. Smith, C. Cobb, and B. Schepps Preferential Use of Sonographically Guided Biopsy to Minimize Patient Discomfort and Procedure Time in a Percutaneous Image-Guided Breast Biopsy Program J. Ultrasound Med., November 1, 2002; 21(11): 1221 - 1226. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Brenner, R. J. Jackman, S. H. Parker, W. P. Evans III, L. Philpotts, B. M. Deutch, M. C. Lechner, D. Lehrer, P. Sylvan, R. Hunt, et al. Percutaneous Core Needle Biopsy of Radial Scars of the Breast: When Is Excision Necessary? Am. J. Roentgenol., November 1, 2002; 179(5): 1179 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, J. B. Kaplan, E. A. Morris, A. F. Abramson, J. H. Menell, and D. D. Dershaw To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy? Am. J. Roentgenol., September 1, 2002; 179(3): 679 - 683. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Georgian-Smith, C. D'Orsi, E. Morris, C. F. Clark Jr., E. Liberty, and C. D. Lehman Stereotactic Biopsy of the Breast Using an Upright Unit, a Vacuum-Suction Needle, and a Lateral Arm-Support System Am. J. Roentgenol., April 1, 2002; 178(4): 1017 - 1024. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Perez-Fuentes, I. R. Longobardi, V. F. Acosta, C. E. Marin, and L. Liberman Sonographically Guided Directional Vacuum-Assisted Breast Biopsy: Preliminary Experience in Venezuela Am. J. Roentgenol., December 1, 2001; 177(6): 1459 - 1463. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Lehman, H. J. Sieler-Gutierrez, and D. Georgian-Smith Lateral Approach Biopsy Adapter: Accuracy on an Upright Unit in a Turkey Breast Model Am. J. Roentgenol., October 1, 2001; 177(4): 897 - 899. [Full Text] [PDF] |
||||
![]() |
R. F. Brem, J. M. Schoonjans, S. N. Goodman, A. Nolten, F. B. Askin, and O. M. B. Gatewood Nonpalpable Breast Cancer: Percutaneous Diagnosis with 11- and 8-gauge Stereotactic Vacuum-assisted Biopsy Devices Radiology, June 1, 2001; 219(3): 793 - 796. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough? Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Berg, H. E. Mrose, and O. B. Ioffe Atypical Lobular Hyperplasia or Lobular Carcinoma in Situ at Core-Needle Breast Biopsy Radiology, February 1, 2001; 218(2): 503 - 509. [Abstract] [Full Text] |
||||
![]() |
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy? Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. E. Philpotts, N. A. Shaheen, K. S. Jain, D. Carter, and C. H. Lee Uncommon High-Risk Lesions of the Breast Diagnosed at Stereotactic Core-Needle Biopsy: Clinical Importance Radiology, September 1, 2000; 216(3): 831 - 837. [Abstract] [Full Text] |
||||
![]() |
L. Liberman and M. P. Sama Cost-Effectiveness of Stereotactic 11-Gauge Directional Vacuum-Assisted Breast Biopsy Am. J. Roentgenol., July 1, 2000; 175(1): 53 - 58. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199. [Full Text] [PDF] |
||||
![]() |
W. A. Berg, C. L. Arnoldus, E. Teferra, and M. Bhargavan Biopsy of Amorphous Breast Calcifications: Pathologic Outcome and Yield at Stereotactic Biopsy Radiology, November 1, 2001; 221(2): 495 - 503. [Abstract] [Full Text] [PDF] |
||||