AJR Custom publishing of AJR articles and ARRS Cat. Course
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Singh, S.
Right arrow Articles by Barnes, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Singh, S.
Right arrow Articles by Barnes, G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 172, 803-808, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

Central venous catheter motion: a pitfall in catheter localization on pediatric chest radiography

S Singh, S Royal, G Hedlund and G Barnes
Department of Radiology, The University of Alabama at Birmingham, 35233, USA.

OBJECTIVE: We evaluated central venous catheter motion causing misinterpretation of catheter tip location in pediatric patients and in an experimental model. MATERIALS AND METHODS: After the recognition of clinically significant catheter motion in 12 randomly selected patients, we conducted a prospective 2-month study of chest radiographs in our pediatric care unit and neonatal emergency department. Serial radiographs were examined for change in catheter tip position ascribed to motion artifact. An in vitro model was developed to replicate clinical parameters. Experimentally, catheter movement and exposure time were analyzed and their impact on catheter localization was recorded. RESULTS: In the 12 randomly selected patients, radiographic assessment of central venous catheter tip localization on sequential radiographs caused minor to major misinterpretation of the position of the catheter tip and even total nonvisualization of the catheter. Ten (3.5%) of 352 prospectively interpreted pediatric emergency department radiographs showed similar findings. Catheter motion that caused blurring was reproduced in vitro using radiographic parameters typically used in a clinical setting. CONCLUSION: Catheter motion can cause problems in assessing catheter tip position on pediatric emergency department chest radiographs. We reproduced this phenomenon in an in vitro model. Catheter removal or change in position may be mimicked by this artifact, and patient management may be affected. In our study, catheter localization was affected by catheter motion and exposure time.