AJR AJR Reprints & E-prints Available. Order Today!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Miller, S.
Right arrow Articles by Claussen, C. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miller, S.
Right arrow Articles by Claussen, C. D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 172, 1365-1369, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

MR angiography and flow quantification of the internal mammary artery graft after minimally invasive direct coronary artery bypass

S Miller, AM Scheule, U Hahn, M Jurmann, U Helber, SH Duda, NI Stauder and CD Claussen
Department of Diagnostic Radiology, Eberhard-Karls-University, Tuebingen, Germany.

OBJECTIVE: Six patients who had undergone minimally invasive direct coronary artery bypass surgery were examined to evaluate an MR imaging protocol that provided information about cardiac function, bypass graft patency, and flow characteristics with a single examination. CONCLUSION: Preliminary results suggest that our imaging protocol allows accurate follow-up of patients after minimally invasive direct coronary artery bypass surgery. Bypass graft patency was correctly determined in all patients. In four patients, anastomoses were visualized by MR angiography, and flow measurements revealed a volume range of 28-84 ml/min (native and grafted internal mammary arteries) and a trend for the flow values of bypass grafts to be lower than those of native vessels. Interobserver reproducibility was good (r = .99; slope, .98).
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. I. Stauder, M. Fenchel, H. Stauder, A. Kuttner, A. M. Scheule, U. Kramer, C. D. Claussen, and S. Miller
Assessment of minimally invasive direct coronary artery bypass grafting of the left internal thoracic artery by means of magnetic resonance imaging
J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 607 - 614.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
C R Peebles
Non-invasive coronary imaging: computed tomography or magnetic resonance imaging?
Heart, June 1, 2003; 89(6): 591 - 594.
[Full Text] [PDF]


Home page
RadiologyHome page
N. H. Bunce, C. H. Lorenz, A. S. John, J. R. Lesser, R. H. Mohiaddin, and D. J. Pennell
Coronary Artery Bypass Graft Patency: Assessment with True Fast Imaging with Steady-State Precession versus Gadolinium-enhanced MR Angiography
Radiology, May 1, 2003; 227(2): 440 - 446.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Roentgen Ray Society.