American Journal of Roentgenology, Vol 173, 169-172, Copyright © 1999 by American Roentgen Ray Society
ARTICLES |
J Yee, RK Hung, GA Akerkar and SD Wall
Department of Radiology (114), Veterans Affairs Medical Center, University of California, San Francisco 94121, USA.
OBJECTIVE: The purpose of this study was to compare colonic distention with and without glucagon hydrochloride during CT colonography. SUBJECTS AND METHODS: CT colonography using single breath-hold, thin- section helical technique was performed on 60 patients who were in the supine and prone positions. Magnesium citrate and polyethylene glycol were used for bowel preparation. Colonic air insufflation averaged 30 bulb compressions. Thirty-three patients received IV glucagon (1 mg), and 27 patients did not. The colon was divided into eight segments, and the adequacy of the distention of each segment was evaluated. Overall colonic distention scores, defined as the number of inadequately distended segments (0-8), were recorded for the supine, prone, and combined positions. In the combined position, inadequate distention was defined as identical segments that were inadequately distended in both positions. RESULTS: A total of 960 segments were evaluated: 528 segments in the glucagon group and 432 segments in the nonglucagon group. In the glucagon group, 444 segments (84.1%) were adequately distended. In the nonglucagon group, 365 segments (84.5%) were adequately distended. The median and range for overall colonic distention scores in the supine, prone, and combined positions were 1 (0-3), 1 (0-3), and 0 (0), respectively, for the glucagon group and 1 (0-6), 1 (0-6), and 0 (0-1), respectively, for the nonglucagon group. We found no statistically significant difference in overall colonic distention between the glucagon group and the nonglucagon group for the supine (p = .84), prone (p = .15), or combined (p = .28) positions. CONCLUSION: Glucagon administration before CT colonography does not improve colonic distention.
This article has been cited by other articles:
![]() |
R. L. Van Uitert, R. M. Summers, J. M. White, K. K. Deshpande, J. R. Choi, and P. J. Pickhardt Temporal and Multiinstitutional Quality Assessment of CT Colonography Am. J. Roentgenol., November 1, 2008; 191(5): 1503 - 1508. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Sosna, J. Bar-Ziv, E. Libson, M. Eligulashvili, and A. Blachar CT Colonography: Positioning Order and Intracolonic Pressure Am. J. Roentgenol., October 1, 2008; 191(4): W175 - W180. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. K. Deshpande, R. M. Summers, R. L. Van Uitert, M. Franaszek, L. Brown, A. J. Dwyer, J. G. Fletcher, J. R. Choi, and P. J. Pickhardt Quality Assessment for CT Colonography: Validation of Automated Measurement of Colonic Distention and Residual Fluid Am. J. Roentgenol., December 1, 2007; 189(6): 1457 - 1463. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Torres, S. Szomstein, and S. D. Wexner Virtual Colonoscopy in Colorectal Cancer Screening Surgical Innovation, March 1, 2007; 14(1): 27 - 34. [Abstract] [PDF] |
||||
![]() |
T. Mang, A. Maier, C. Plank, C. Mueller-Mang, C. Herold, and W. Schima Pitfalls in Multi-Detector Row CT Colonography: A Systematic Approach RadioGraphics, March 1, 2007; 27(2): 431 - 454. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. J. Shinners, P. J. Pickhardt, A. J. Taylor, D. A. Jones, and C. H. Olsen Patient-controlled room air insufflation versus automated carbon dioxide delivery for CT colonography. Am. J. Roentgenol., June 1, 2006; 186(6): 1491 - 1496. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Burling, S. A. Taylor, S. Halligan, L. Gartner, M. Paliwalla, C. Peiris, L. Singh, P. Bassett, and C. Bartram Automated Insufflation of Carbon Dioxide for MDCT Colonography: Distension and Patient Experience Compared with Manual Insufflation Am. J. Roentgenol., January 1, 2006; 186(1): 96 - 103. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Macari and E. J. Bini CT Colonography: Where Have We Been and Where Are We Going? Radiology, December 1, 2005; 237(3): 819 - 833. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Kim, J. M. Lee, J. K. Han, J. Y. Lee, H. K. Yang, H.-J. Lee, K.-S. Shin, and B. I. Choi Effect of Adjusted Positioning on Gastric Distention and Fluid Distribution During CT Gastrography Am. J. Roentgenol., November 1, 2005; 185(5): 1180 - 1184. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Rogalla, A. Lembcke, J. C. Ruckert, E. Hein, M. Bollow, N. E. Rogalla, and B. Hamm Spasmolysis at CT Colonography: Butyl Scopolamine versus Glucagon Radiology, July 1, 2005; 236(1): 184 - 188. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Barish, J. A. Soto, and J. T. Ferrucci Consensus on Current Clinical Practice of Virtual Colonoscopy Am. J. Roentgenol., March 1, 2005; 184(3): 786 - 792. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Cohnen, C. Vogt, A. Beck, K. Andersen, W. Heinen, S. vom Dahl, V. Aurich, D. Haeussinger, and U. Moedder Feasibility of MDCT Colonography in Ultra-Low-Dose Technique in the Detection of Colorectal Lesions: Comparison with High-Resolution Video Colonoscopy Am. J. Roentgenol., November 1, 2004; 183(5): 1355 - 1359. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. E. van Gelder, E. Birnie, J. Florie, M. P. Schutter, J. F. Bartelsman, P. Snel, J. S. Lameris, G. J. Bonsel, and J. Stoker CT Colonography and Colonoscopy: Assessment of Patient Preference in a 5-week Follow-up Study Radiology, November 1, 2004; 233(2): 328 - 337. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. F. Geenen, S. M. Hussain, F. Cademartiri, J.-W. Poley, P. D. Siersema, and G. P. Krestin CT and MR Colonography: Scanning Techniques, Postprocessing, and Emphasis on Polyp Detection RadioGraphics, January 1, 2004; 24(1): e18 - e18. [Abstract] [Full Text] |
||||
![]() |
S. A. Taylor, S. Halligan, V. Goh, S. Morley, P. Bassett, W. Atkin, and C. I. Bartram Optimizing Colonic Distention for Multi-Detector Row CT Colonography: Effect of Hyoscine Butylbromide and Rectal Balloon Catheter Radiology, October 1, 2003; 229(1): 99 - 108. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Macari, E. J. Bini, S. L. Jacobs, N. Lange, and Y. W. Lui Filling Defects at CT Colonography: Pseudo- and Diminutive Lesions (The Good), Polyps (The Bad), Flat Lesions, Masses, and Carcinomas (The Ugly) RadioGraphics, September 1, 2003; 23(5): 1073 - 1091. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Yee, N. N. Kumar, R. K. Hung, G. A. Akerkar, P. R. G. Kumar, and S. D. Wall Comparison of Supine and Prone Scanning Separately and in Combination at CT Colonography Radiology, March 1, 2003; 226(3): 653 - 661. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. G. McFarland, T. K. Pilgram, J. A. Brink, R. A. McDermott, C. V. Santillan, P. W. Brady, J. P. Heiken, D. M. Balfe, L. B. Weinstock, E. P. Thyssen, et al. CT Colonography: Multiobserver Diagnostic Performance Radiology, November 1, 2002; 225(2): 380 - 390. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. W. Hung, D. S. Paik, S. Napel, J. Yee, R. B. Jeffrey Jr, A. Steinauer-Gebauer, J. Min, A. Jathavedam, and C. F. Beaulieu Quantification of Distention in CT Colonography: Development and Validation of Three Computer Algorithms Radiology, February 1, 2002; 222(2): 543 - 554. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Yee, G. A. Akerkar, R. K. Hung, A. M. Steinauer-Gebauer, S. D. Wall, and K. R. McQuaid Colorectal Neoplasia: Performance Characteristics of CT Colonography for Detection in 300 Patients Radiology, June 1, 2001; 219(3): 685 - 692. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. K. Hara, C. D. Johnson, R. L. MacCarty, T. J. Welch, C. H. McCollough, and W. S. Harmsen CT Colonography: Single- versus Multi-Detector Row Imaging Radiology, May 1, 2001; 219(2): 461 - 465. [Abstract] [Full Text] |
||||
![]() |
B. M. Preston Rethinking the Use of Glucagon: Consider the Cost Am. J. Roentgenol., February 1, 2001; 176(2): 546 - 547. [Full Text] [PDF] |
||||
![]() |
E. G. McFarland, J. A. Brink, T. K. Pilgram, J. P. Heiken, D. M. Balfe, D. A. Hirselj, L. Weinstock, and B. Littenberg Spiral CT Colonography: Reader Agreement and Diagnostic Performance with Two- and Three-dimensional Image-Display Techniques Radiology, February 1, 2001; 218(2): 375 - 383. [Abstract] [Full Text] |
||||
![]() |
M. Macari, M. Lavelle, I. Pedrosa, A. Milano, M. Dicker, A. J. Megibow, and X. Xue Effect of Different Bowel Preparations on Residual Fluid at CT Colonography Radiology, January 1, 2001; 218(1): 274 - 277. [Abstract] [Full Text] |
||||
![]() |
R. Levatter and J. Yee Rethinking the Argument Against Glucagon for CT Colonography Am. J. Roentgenol., June 1, 2000; 174(6): 1787 - 1787. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |