AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Damascelli, B.
Right arrow Articles by Vespro, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Damascelli, B.
Right arrow Articles by Vespro, V.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 173, 895-900, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

Stereotactic breast biopsy: en bloc excision of microcalcifications with a large-bore cannula device

B Damascelli, LF Frigerio, G Patelli, R Lanocita, G Viganotti, E Uslenghi, V Ticha, A Conti, S Bohm, T De Simone and V Vespro
Department of Radiology, National Cancer Institute, Milano, Italy.

OBJECTIVE: Breast calcifications pose a significant diagnostic and procedural dilemma. We evaluated en bloc stereotactic excision of indeterminate and suggestive microcalcifications for histologic diagnosis using a large-bore cannula biopsy device. MATERIALS AND METHODS: We retrospectively reviewed 61 groups of microcalcifications removed with a large-bore cannula biopsy device from 59 patients (age range, 35-72 years old). The cannula diameter was 20 mm in 47 cases, 15 mm in nine cases, and 10 mm in five cases. The median lesion diameter was 6.6 mm (range, 4-17 mm). The procedure was performed by radiologists in an outpatient setting, with patients undergoing local anesthesia. All patients with a diagnosis of malignancy underwent surgery. RESULTS: In all instances, microcalcifications were removed in a single pass, in a single intact tissue specimen, through a maximum skin incision of 2 cm (0.8 inch). Twenty-five malignancies, 34 benign lesions, and two cases of lobular carcinoma in situ were identified. Sixteen malignancies were noninvasive and nine were invasive. No residual tumor was found at surgery in six of the 18 cases with involved margins and in five of the seven cases with uninvolved margins. One case of lobular carcinoma in situ with involvement of the margins additionally showed ductal carcinoma in situ at surgery. CONCLUSION: Mammographically identified microcalcifications are excised en bloc with the large-bore cannula biopsy device, providing a stereotactically localized tissue sample that is comparable with that obtained with open surgical biopsy and allows evaluation of the margins. This surgical radiologic procedure may represent a valid alternative, in selected patients, to conventional surgical biopsy after radiologic localization.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
D. E. March, B. F. Coughlin, R. B. Barham, R. A. Goulart, S. V. Klein, M. E. Bur, J. L. Frank, and G. Makari-Judson
Breast Masses: Removal of All US Evidence during Biopsy by Using a Handheld Vacuum-assisted Device--Initial Experience
Radiology, May 1, 2003; 227(2): 549 - 555.