AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ramaswamy, M. R.
Right arrow Articles by vanSonnenberg, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ramaswamy, M. R.
Right arrow Articles by vanSonnenberg, E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2000; 174:617-622
© American Roentgen Ray Society


Continuous Speech Recognition in MR Imaging Reporting

Advantages, Disadvantages, and Impact

Mohan R. Ramaswamy1,2, Gregory Chaljub1, Oliver Esch1, Donald D. Fanning1 and Eric vanSonnenberg1,3

1 Department of Radiology, University of Texas Medical Branch, 301 University Blvd., Galveston, TX 77555-0465.
2 Present address: Department of Radiology, University of California, S.F.G.H. (Bldg. NH, Rm. G100), 1001 Potrero Ave., San Francisco, CA 94110.
3 Present address: Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis St., Boston, MA 02115.

OBJECTIVE. Our objective was to describe our experience with a commercially available continuous speech recognition system, highlighting the advantages, disadvantages, and costs compared with those of conventional transcription for MR imaging reports.

MATERIALS AND METHODS. Data from 5072 reports generated in our MR imaging section during a 9-month period after the implementation of a commercial continuous speech recognition system were compared with 4552 reports produced during the same period 1 year earlier. Information pertaining to the use of continuous speech recognition, report turnaround time, word recognition rate, report appearance, and equipment costs was collected.

RESULTS. After its system installation, continuous speech recognition was used to dictate 81.8% of all reports. The mean report turnaround time decreased from 87.8 to 43.6 hr, and report availability at 24 hr increased from 10.5% to 62.5%. The system was found to have an average word recognition accuracy of 92.7% for spontaneous dictation. Mean report length declined from 95 to 60 words, with an increase in spacing errors from 0.3 to 8.0 per 1000 words and a decrease in spelling errors from 3.0 to 0.8 per 1000 words. Initial hardware and software costs were approximately $10,000, compared with a yearly cost of $12,000 for human transcription.

CONCLUSION. Although the technology is still evolving and was evaluated in its earliest implementation stages, continuous speech recognition nonetheless markedly improved report turnaround time and proved cost-effective.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
D. L. Weiss and C. P. Langlotz
Structured Reporting: Patient Care Enhancement or Productivity Nightmare?
Radiology, December 1, 2008; 249(3): 739 - 747.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S McGURK, K BRAUER, T V MACFARLANE, and K A DUNCAN
The effect of voice recognition software on comparative error rates in radiology reports
Br. J. Radiol., October 1, 2008; 81(970): 767 - 770.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Roentgen Ray Society.