AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haage, P.
Right arrow Articles by Günther, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haage, P.
Right arrow Articles by Günther, R. W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2000; 174:1049-1053
© American Roentgen Ray Society


Reduction of Contrast Material Dose and Artifacts by a Saline Flush Using a Double Power Injector in Helical CT of the Thorax

Patrick Haage1, Thomas Schmitz-Rode, Dolores Hübner, Werner Piroth and Rolf W. Günther

1 All authors: Department of Diagnostic Radiology, University of Technology, Pauwelsstra. 30, D-52057 Aachen, Germany.

OBJECTIVE. Our objective was to evaluate a combined method of contrast material bolus followed by saline solution flush for thoracic helical CT and statistical comparison with a uniphasic injection protocol.

MATERIALS AND METHODS. Fifty patients underwent helical CT of the thorax using 60 ml of contrast material (370 mg I/ml) followed by flushing with 30 ml of physiologic saline solution. These 50 patients had been examined before using our previous protocol, 75 ml of the same contrast material without a subsequent saline solution. Mean attenuation values for both protocols were measured in the superior vena cava, the pulmonary trunk, and the ascending aorta. Image artifacts and mediastinal and hilar depiction were graded and compared.

RESULTS. Mean attenuation values in the superior vena cava were considerably higher in the regimen without saline solution flush (459 H versus 352 H) and in the pulmonary trunk and the ascending aorta were almost identical for both protocols. Injection of saline solution diminished surrounding artifacts (p = 0.001). Grading results for the evaluation of mediastinal and hilar structures were not significantly different in the two protocols (p = 0.564).

CONCLUSION. Injection of contrast material followed by a saline solution bolus using a double power injector when performing thoracic helical CT allows a 20% reduction of contrast material volume to 60 ml with a similar degree of enhancement. In addition, perivenous artifacts in the superior vena cava are significantly reduced.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
J. M. Kerl, J. G. Ravenel, S. A. Nguyen, P. Suranyi, C. Thilo, P. Costello, W. Bautz, and U. J. Schoepf
Right Heart: Split-Bolus Injection of Diluted Contrast Medium for Visualization at Coronary CT Angiography
Radiology, May 1, 2008; 247(2): 356 - 364.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. J. Kim, T. H. Kim, S. J. Kim, D. P. Kim, C. S. Oh, Y. H. Ryu, Y. J. Kim, and B. W. Choi
Saline Flush Effect for Enhancement of Aorta and Coronary Arteries at Multidetector CT Coronary Angiography
Radiology, January 1, 2008; 246(1): 110 - 115.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. M. Ho, R. C. Nelson, and D. M. DeLong
Determining Contrast Medium Dose and Rate on Basis of Lean Body Weight: Does This Strategy Improve Patient-to-Patient Uniformity of Hepatic Enhancement during Multi-Detector Row CT?
Radiology, May 1, 2007; 243(2): 431 - 437.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Uchiyama, K. Fujimoto, M. Uchida, M. Koganemaru, T. Urae, and N. Hayabuchi
Bronchial Arteriovenous Malformation: MDCT Angiography Findings
Am. J. Roentgenol., May 1, 2007; 188(5): W409 - W411.
[Full Text] [PDF]


Home page
Br. J. Radiol.Home page
F Tatsugami, M Matsuki, Y Inada, G Nakai, M Tanikake, S Yoshikawa, and I Narabayashi
Usefulness of saline pushing in reduction of contrast material dose in abdominal CT: evaluation of time-density curve for the aorta, portal vein and liver
Br. J. Radiol., April 1, 2007; 80(952): 231 - 234.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. H. Lee, J. M. Goo, H. J. Lee, K. G. Kim, J.-G. Im, and K. T. Bae
Determination of Optimal Timing Window for Pulmonary Artery MDCT Angiography
Am. J. Roentgenol., February 1, 2007; 188(2): 313 - 317.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. Orlandini, S. Boini, S. Iochum-Duchamps, T. Batch, X. Zhu, and A. Blum
Assessment of the use of a saline chaser to reduce the volume of contrast medium in abdominal CT.
Am. J. Roentgenol., August 1, 2006; 187(2): 511 - 515.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Kubo, E. Tadamura, M. Yamamuro, R. Hosokawa, T. Kimura, T. Kita, M. Komeda, and K. Togashi
Thoracoabdominal-aortoiliac MDCT angiography using reduced dose of contrast material.
Am. J. Roentgenol., August 1, 2006; 187(2): 548 - 554.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. de Monye, T. T. de Weert, W. Zaalberg, F. Cademartiri, D. A. M. Siepman, D. W. J. Dippel, and A. van der Lugt
Optimization of CT angiography of the carotid artery with a 16-MDCT scanner: craniocaudal scan direction reduces contrast material-related perivenous artifacts.
Am. J. Roentgenol., June 1, 2006; 186(6): 1737 - 1745.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Utsunomiya, K. Awai, Y. Tamura, T. Nishiharu, J. Urata, T. Sakamoto, A. Taniguchi, and Y. Yamashita
16-MDCT Aortography with a Low-Dose Contrast Material Protocol
Am. J. Roentgenol., February 1, 2006; 186(2): 374 - 378.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Awai, A. Hatcho, Y. Nakayama, S. Kusunoki, D. Liu, M. Hatemura, Y. Funama, M. Denbo, N. Sato, and Y. Yamashita
Simulation of Aortic Peak Enhancement on MDCT Using a Contrast Material Flow Phantom: Feasibility Study
Am. J. Roentgenol., February 1, 2006; 186(2): 379 - 385.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. de Monye, F. Cademartiri, T. T. de Weert, D. A. M. Siepman, D. W. J. Dippel, and A. van Der Lugt
Sixteen-Detector Row CT Angiography of Carotid Arteries: Comparison of Different Volumes of Contrast Material with and without a Bolus Chaser
Radiology, November 1, 2005; 237(2): 555 - 562.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Schoellnast, H. A. Deutschmann, G. A. Fritz, U. Stessel, G. J. Schaffler, and M. Tillich
MDCT Angiography of the Pulmonary Arteries: Influence of Iodine Flow Concentration on Vessel Attenuation and Visualization
Am. J. Roentgenol., June 1, 2005; 184(6): 1935 - 1939.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, M. Inoue, Y. Yagyu, M. Watanabe, T. Sano, S. Nin, R. Koike, Y. Nishimura, and Y. Yamashita
Moderate versus High Concentration of Contrast Material for Aortic and Hepatic Enhancement and Tumor-to-Liver Contrast at Multi-Detector Row CT
Radiology, December 1, 2004; 233(3): 682 - 688.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. J. Schoepf and P. Costello
CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art
Radiology, February 1, 2004; 230(2): 329 - 337.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Loubeyre, I. Debard, C. Nemoz, and V. A. T. Minh
High Opacification of Hilar Pulmonary Vessels with a Small Amount of Nonionic Contrast Medium for General Thoracic CT: A Prospective Study
Am. J. Roentgenol., June 1, 2002; 178(6): 1377 - 1381.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Roentgen Ray Society.