OBJECTIVE. We tested breath-held 1-mm multislice helical CT for obtaining both contiguous and high-resolution CT sections of the chest from a single set of raw data.
SUBJECTS AND METHODS. Seventy patients with suspected focal and diffuse lung disease were allocated into two groups for comparison. The first group (n = 35) underwent multislice helical CT of the chest with 1-mm collimation and a pitch of 6. From the raw data, 5-mm contiguous and 1.25-mm high-resolution CT sections were reconstructed. The second group (n = 35) underwent conventional single-slice helical CT and high-resolution CT. High-resolution CT sections and 5-mm scans were rated for overall image quality, spatial resolution, subjective signal-to-noise ratio, diagnostic value, depiction of bronchi and parenchyma, and motion and streak artifacts. The 5-mm scans were also rated for contrast resolution and depiction of the heart and vessels. Radiation dose was calculated.
RESULTS. We rated 5-mm multislice helical CT superior to 5-mm single-slice helical CT, having a significantly higher total score (p = 0.0001). No significant difference (p = 0.986) was found between multislice and single-slice high-resolution CT sections. Radiation dose was 5.55 mSv for multislice helical CT and 5.50 mSv for single-slice helical CT.
CONCLUSION. Contiguous chest scans of superior quality and high-resolution CT sections of equal image quality compared with single-slice helical CT can be obtained using multislice helical CT. Therefore, a comprehensive diagnosis is feasible in patients with suspected focal and diffuse lung disease by obtaining a single scan.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
D. K. Yousefzadeh, M. B. Ward, and C. Reft Internal Barium Shielding to Minimize Fetal Irradiation in Spiral Chest CT: A Phantom Simulation Experiment. Radiology, June 1, 2006; 239(3): 751 - 758. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Studler, T. Gluecker, G. Bongartz, J. Roth, and W. Steinbrich Image Quality from High-Resolution CT of the Lung: Comparison of Axial Scans and of Sections Reconstructed from Volumetric Data Acquired Using MDCT Am. J. Roentgenol., September 1, 2005; 185(3): 602 - 607. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. G. Flohr, S. Schaller, K. Stierstorfer, H. Bruder, B. M. Ohnesorge, and U. J. Schoepf Multi-Detector Row CT Systems and Image-Reconstruction Techniques Radiology, June 1, 2005; 235(3): 756 - 773. [Abstract] [Full Text] [PDF] |
||||
![]() |
W K Chooi and S K Morcos High resolution volume imaging of airways and lung parenchyma with multislice CT Br. J. Radiol., December 1, 2004; 77(suppl_1): S98 - S105. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. J. Schoepf and P. Costello CT Angiography for Diagnosis of Pulmonary Embolism: State of the Art Radiology, February 1, 2004; 230(2): 329 - 337. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Coche, F. Verschuren, A. Keyeux, P. Goffette, L. Goncette, P. Hainaut, F. Hammer, E. Lavenne, F. Zech, P. Meert, et al. Diagnosis of Acute Pulmonary Embolism in Outpatients: Comparison of Thin-Collimation Multi-Detector Row Spiral CT and Planar Ventilation-Perfusion Scintigraphy Radiology, December 1, 2003; 229(3): 757 - 765. [Abstract] [Full Text] [PDF] |
||||
![]() |
W K Chooi, S Matthews, M J Bull, and S K Morcos Multislice helical CT: the value of multiplanar image reconstruction in assessment of the bronchi and small airways disease Br. J. Radiol., August 1, 2003; 76(908): 536 - 540. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Catalano, F. Fraioli, A. Laghi, A. Napoli, F. Pediconi, M. Danti, P. Nardis, and R. Passariello High-Resolution Multidetector CT in the Preoperative Evaluation of Patients with Renal Cell Carcinoma Am. J. Roentgenol., May 1, 2003; 180(5): 1271 - 1277. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. J. Schoepf, N. Holzknecht, T. K. Helmberger, A. Crispin, C. Hong, C. R. Becker, and M. F. Reiser Subsegmental Pulmonary Emboli: Improved Detection with Thin-Collimation Multi-Detector Row Spiral CT Radiology, February 1, 2002; 222(2): 483 - 490. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |