AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Awai, K.
Right arrow Articles by Hori, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Awai, K.
Right arrow Articles by Hori, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2001; 177:1141-1144
© American Roentgen Ray Society


Selenium-Based Digital Radiography Versus High-Resolution Storage Phosphor Radiography in the Detection of Solitary Pulmonary Nodules Without Calcification

Receiver Operating Characteristic Curve Analysis

Kazuo Awai1, Masanori Komi and Shinichi Hori

1 All authors: Department of Radiology, Rinku General Medical Center, 2-23 Rinku-orai-kita, Izumisano, Osaka 598-8577, Japan.

OBJECTIVE. The purpose of this study was to compare selenium-based digital radiography with high-resolution storage phosphor radiography for the detection of solitary pulmonary nodules without calcification.

MATERIALS AND METHODS. One hundred twenty-four patients underwent selenium-based digital radiography, high-resolution storage phosphor radiography, and chest CT for evaluation of pulmonary nodules. Thirty-one patients with pulmonary nodules smaller than 3 cm in diameter and 40 patients with normal lungs were selected for receiver operating characteristic curve analysis. Five board-certified radiologists who were unaware of the CT results independently reviewed each of the hard copies of selenium-based digital radiography and storage phosphor radiography, identified pulmonary nodules, and graded their confidence for the presence of each nodule. For each radiologist, we calculated the areas under the receiver operating characteristic curve (AUC) for selenium-based digital radiography and storage phosphor radiography.

RESULTS. The average performance of selenium-based digital radiography (AUC = 0.72) was higher than that of high-resolution storage phosphor radiography (AUC = 0.64), which is statistically significant (p <0.05).

CONCLUSION. Our results indicate that selenium-based digital radiography is superior to high-resolution storage phosphor radiography for detecting solitary pulmonary nodules without calcification.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
S. Wirth, M. Treitl, M. F. Reiser, and M. Korner
Imaging Performance with Different Doses in Skeletal Radiography: Comparison of a Needle-structured and a Conventional Storage Phosphor System with a Flat-Panel Detector
Radiology, November 10, 2008; (2008) 2493080640.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
K. Bacher, P. Smeets, L. Vereecken, A. De Hauwere, P. Duyck, R. De Man, K. Verstraete, and H. Thierens
Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems.
Am. J. Roentgenol., September 1, 2006; 187(3): 630 - 637.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K Ono, T Yoshitake, K Akahane, Y Yamada, T Maeda, M Kai, and T Kusama
Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinoma lesions using hard copy images
Br. J. Radiol., October 1, 2005; 78(934): 922 - 927.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, M. V. Boot, and J. Geleijns
Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease
Am. J. Roentgenol., August 1, 2005; 185(2): 339 - 346.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.