AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Carr, J. C.
Right arrow Articles by Finn, J. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Carr, J. C.
Right arrow Articles by Finn, J. P.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2002; 178:543-549
© American Roentgen Ray Society


High-Resolution Breath-Hold Contrast-Enhanced MR Angiography of the Entire Carotid Circulation

James C. Carr1, Jason Ma2, Vibhas Desphande2, Scott Pereles1, Gerhard Laub3 and J. Paul Finn2

1 Department of Radiology, Northwestern University Medical School, 676 St. Clair St., 8th Floor, Chicago, IL 60611.
2 Department of Biomedical Engineering, Northwestern University Medical School, Chicago, IL 60611.
3 Siemens Research and Development, 448 E. Ontario St., Chicago, IL 60611.

OBJECTIVE. The purpose of this study was to evaluate the effect of breathing on image quality of the aortic arch and carotid vessels during contrast-enhanced MR angiography and to show that high-resolution breath-hold contrast-enhanced MR angiography combined with a timing-bolus technique can produce high-quality images of the entire carotid circulation.

MATERIALS AND METHODS. Forty patients underwent high-resolution contrast-enhanced MR angiography on a 1.5-T Magnetom Symphony. A coronal three-dimensional (3D) gradient-echo sequence (TR/TE, 4.36/1.64; flip angle, 25°) with asymmetric k-space acquisition was used. The 136 x 512 matrix yielded voxel sizes of 1.33 x 0.64 x 1.0 mm. A timing-bolus acquisition, orientated in the coronal plane to include the aortic arch, was obtained initially during free-breathing. Twenty milliliters of gadopenetate dimeglumine was injected at 2 mL/sec. Unenhanced and enhanced 3D volumes were recorded. A subtracted 3D set was calculated and subjected to a maximum-intensity-projection algorithm. Half of the patients held their breath during angiography and the other half did not. Aortic arch motion was measured on the timing-bolus acquisition as the distance moved by a single pixel in both the x and y directions. Maximum-intensity-projection MR images were assessed independently by two observers, and vessel sharpness was scored on a scale of 1-5. Sharpness was also assessed quantitatively by generating a signal intensity profile across the aortic arch vessel wall and calculating the average of the upslope and downslope at full-width half maximum. Visualization of carotid branch vessels was scored on a scale of 0-5, and venous contamination was scored on a scale of 0-3.

RESULTS. Average in-plane aortic arch movement was 10.3 mm in the x direction and 8.7 mm in the y direction. Quantitative and qualitative sharpness of the aortic arch and great vessel origins was better (p < 0.05) during breath-holding than during non—breath-holding. No difference in the sharpness of the carotid vessels was noted between the two groups. Carotid branch vessels were well visualized from the aortic arch to the intracerebral circulation. The average venous contamination score was 0.56.

CONCLUSION. Breath-holding greatly improves the sharpness of the aortic arch and great vessel origins but has no effect on visualization of the carotid vessels. High-resolution breath-hold contrast-enhanced MR angiography can produce high-quality, artifact-free images of the entire carotid circulation from the aortic arch to the intracerebral circulation.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
A. Tomasian, N. Salamon, D. G. Lohan, M. Jalili, J. P. Villablanca, and J. P. Finn
Supraaortic Arteries: Contrast Material Dose Reduction at 3.0-T High-Spatial-Resolution MR Angiography--Feasibility Study
Radiology, December 1, 2008; 249(3): 980 - 990.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
R.S. Saleh, D.G. Lohan, J.P. Villablanca, G. Duckwiler, S.T. Kee, and J.P. Finn
Assessment of Craniospinal Arteriovenous Malformations at 3T with Highly Temporally and Highly Spatially Resolved Contrast-Enhanced MR Angiography
AJNR Am. J. Neuroradiol., May 1, 2008; 29(5): 1024 - 1031.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. M. Groves, W. Bireley, K. Dill, T. J. Carroll, and J. C. Carr
Quantitative Analysis of ECG-Gated High-Resolution Contrast-Enhanced MR Angiography of the Thoracic Aorta
Am. J. Roentgenol., February 1, 2007; 188(2): 522 - 528.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Nael, J. P. Villablanca, W. B. Pope, T. O. McNamara, G. Laub, and J. P. Finn
Supraaortic Arteries: Contrast-enhanced MR Angiography at 3.0 T--Highly Accelerated Parallel Acquisition for Improved Spatial Resolution over an Extended Field of View
Radiology, February 1, 2007; 242(2): 600 - 609.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
C. W. Yang, J. C. Carr, S. F. Futterer, M. D. Morasch, B. P. Yang, S. M. Shors, and J. P. Finn
Contrast-Enhanced MR Angiography of the Carotid and Vertebrobasilar Circulations
AJNR Am. J. Neuroradiol., September 1, 2005; 26(8): 2095 - 2101.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Wu, J. Zhang, C. J. Ladner, J. S. Babb, P. J. Lamparello, and G. A. Krinsky
Subclavian Steal Syndrome: Diagnosis with Perfusion Metrics from Contrast-enhanced MR Angiographic Bolus-timing Examination--Initial Experience
Radiology, June 1, 2005; 235(3): 927 - 933.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Krinsky
Evaluation of Arch Vessels: Breath-hold versus Non-Breath-hold Techniques [letter]
Radiology, July 1, 2004; 232(1): 303 - 304.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Roentgen Ray Society.