AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jeong, J. Y.
Right arrow Articles by Choi, B. I.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jeong, J. Y.
Right arrow Articles by Choi, B. I.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2002; 178:847-852
© American Roentgen Ray Society


Fluoroscopically Guided Placement of a Covered Self-Expandable Metallic Stent for Malignant Antroduodenal Obstructions

Preliminary Results in 18 Patients

Jun Yong Jeong1,2, Joon Koo Han, Ah Young Kim, Kyoung Ho Lee, Jae Young Lee, Joon-Won Kang, Tae Jung Kim, Shang Hoon Shin and Byung Ihn Choi

1 All authors: Department of Radiology, Seoul National University College of Medicine, 28 Yongon-dong, Chongno-gu, Seoul 110-744, Korea.
2 All authors: Institute of Radiation Medicine, Seoul National University College of Medicine, Clinical Research Institute, Seoul National University Hospital, Seoul 110-744, Korea.

OBJECTIVE. The purpose of this study was to investigate the technical feasibility and the clinical effectiveness of fluoroscopically guided placement of covered self-expandable metallic stents in the treatment of malignant antroduodenal obstructions.

SUBJECTS AND METHODS. With fluoroscopic guidance, covered self-expandable metallic stents were placed in 18 consecutive patients with inoperable malignant antroduodenal obstructions. All patients were treated for severe nausea and recurrent vomiting.

RESULTS. Stent placement was technically successful in all patients with or without gastrostomy (n = 2) and balloon dilatation (n = 3). After stent placement, symptoms improved in all but one patient, who had another stenosis in the proximal jejunum. During the follow-up of 2-73 weeks (mean, 12 weeks), stent migration occurred in three patients (16.7%) from 1 to 41 days after the procedure. These patients were treated successfully by means of placing a second covered metallic stent. Two patients, who were followed up for longer than 30 weeks, showed a recurrence of strictures because of mechanical failure of the stents; one of the patients was treated with coaxial placement of a second covered metallic stent, which had a positive clinical outcome.

CONCLUSION. Fluoroscopically guided placement of covered self-expandable metallic stents is technically feasible and effective for the palliative treatment of inoperable malignant antroduodenal obstructions. The rate of stent migration in our study was lower than those in previous reports.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. H. Kim, H.-Y. Song, J. H. Shin, E. Choi, T. W. Kim, S. K. Lee, and B. S. Kim
Stent Collapse as a Delayed Complication of Placement of a Covered Gastroduodenal Stent
Am. J. Roentgenol., June 1, 2007; 188(6): 1495 - 1499.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. E. Lopera, A. Brazzini, A. Gonzales, and W. R. Castaneda-Zuniga
Gastroduodenal Stent Placement: Current Status
RadioGraphics, November 1, 2004; 24(6): 1561 - 1573.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Roentgen Ray Society.