AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ruel, L.
Right arrow Articles by Rahmouni, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ruel, L.
Right arrow Articles by Rahmouni, A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2004; 182:749-755
© American Roentgen Ray Society


Comparison of In Vitro and In Vivo MRI of the Spine Using Parallel Imaging

Lucile Ruel1, Pierre Brugières1, Alain Luciani1, Stéphane Breil2, Didier Mathieu1 and Alain Rahmouni1

1 Départment Imagerie Médicale, Centre Hospitalo-Universitaire Henri Mondor, Université de Créteil, Paris XII, 51 Ave. du Mal de Lattre de Tassigny, Créteil 94010 Cedex, France.
2 Siemens SAS, Division Médicale, 39/47, Blvd. Ornano, Saint-Denis 93527 Cedex 2, France.

OBJECTIVE. The purpose of this study was to compare the image quality of two parallel-imaging methods applied to standard turbo spin-echo T2-weighted imaging of the lumbar spine.

MATERIALS AND METHODS. Phantom imaging and lumbar spine studies of 15 healthy subjects were performed using T2-weighted turbo spin-echo sequences obtained with and without parallel imaging (generalized autocalibrating partially parallel acquisition [GRAPPA] and modified sensitive encoding [mSENSE]) on a 1.5-T magnet. The signal-to-noise ratio (SNR) and uniformity were measured in the phantom, and SNR and signal difference–noise ratio were evaluated in cerebrospinal fluid, vertebral bodies, and subcutaneous fat of the volunteers, using both techniques sequentially. Aliasing artifacts on GRAPPA and mSENSE images were visually evaluated. SNRs were compared using the Student's paired t test, with p values less than 0.05 considered significant.

RESULTS. In the phantom study, when the same number of coil elements were used (n = 3), SNR and uniformity values obtained with standard T2-weighted turbo spin-echo sequences were higher than those obtained with parallel sequences. The GRAPPA SNR obtained with three coil elements was higher than the standard T2-weighted SNR obtained with one coil element. Similar findings were noted regarding uniformity. In the lumbar spine, GRAPPA SNR values for fat, cerebrospinal fluid, and vertebral bodies were significantly higher than mSENSE SNR values, with a p value less than 0.01, but were not significantly different from T2-weighted turbo spin-echo SNR values. GRAPPA signal difference–noise ratio values were significantly higher than mSENSE signal difference–noise ratio values, with a p value less than 0.01, but were not significantly different from T2-weighted turbo spin-echo signal difference–noise ratio values. GRAPPA produced fewer aliasing artifacts than mSENSE.

CONCLUSION. In spine MRI, GRAPPA may be used to reduce scanning time and yields a higher SNR than mSENSE without any increase in aliasing artifacts and with an SNR similar to that obtained with standard T2-weighted turbo spin-echo.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
Y.A. Bhagat, D.J. Emery, S. Naik, T. Yeo, and C. Beaulieu
Comparison of Generalized Autocalibrating Partially Parallel Acquisitions and Modified Sensitivity Encoding for Diffusion Tensor Imaging
AJNR Am. J. Neuroradiol., February 1, 2007; 28(2): 293 - 298.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.