AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kim, J. K.
Right arrow Articles by Cho, K.-S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kim, J. K.
Right arrow Articles by Cho, K.-S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2004; 183:471-477
© American Roentgen Ray Society


CT Angiography for Evaluation of Living Renal Donors: Comparison of Four Reconstruction Methods

Jeong Kon Kim1, Jin Hyoung Kim1, Sang-Jin Bae2 and Kyoung-Sik Cho1

1 Department of Radiology, Asan Medical Center, University of Ulsan, College of Medicine, 388-1 Poongnap-dong, Songpa-gu, Seoul 138-736, South Korea.
2 Department of Radiology, Inje University, Sanggyepaik Hospital, Seoul 139-707, South Korea.

OBJECTIVE. We sought to compare various reconstruction methods for CT angiographic images in evaluating living renal donors.

MATERIALS AND METHODS. In 76 patients who underwent donor nephrectomy, vascular phase CT data were obtained using an MDCT scanner (detector array, 1.25 mm x 4; beam pitch, 1.5). Two radiologists independently reconstructed CT angiographic images using thick-slab volume rendering, thick-slab maximum intensity projection (MIP), sliding thin-slab volume rendering, and sliding thin-slab MIP. The radiologists counted the number of renal arteries, early branching arteries, and renal veins. We compared the accuracy rates for the detection of vessels achieved with the four types of reconstructed images, using the surgical findings as the gold standard. Agreement between the two observers and between the surgical and CT angiographic findings was evaluated.

RESULTS. The sensitivity for detecting the supernumerary artery was significantly greater with sliding thin-slab volume rendering and sliding thin-slab MIP (97%) than with thick-slab volume rendering (59%) (p = 0.039). No significant difference between the other comparison pairs of reconstruction methods was found. The interobserver agreement for detecting supernumerary and early branching arteries with sliding thin-slab volume rendering and MIP was excellent ({kappa} = 0.820-0.859) and good for renal veins ({kappa} = 0.698-0.724), whereas the agreement of thick-slab volume rendering and MIP was good for arteries ({kappa} = 0.706-0.791) and moderate for veins ({kappa} = 0.443-0.579). The agreement between CT angiographic reconstructed images and surgical findings for detection of vessels was better with sliding thin-slab volume rendering and MIP ({kappa} = 0.793-1.000) than in thick-slab volume rendering and MIP ({kappa} = 0.306-0.613).

CONCLUSION. For CT angiographic evaluation of living renal donors, sliding thin-slab reconstruction is superior to thick-slab reconstruction.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
A. K. Singh, D. V. Sahani, C. R. Kagay, S. P. Kalva, M. C. Joshi, N. Elias, and T. Kawai
Semiautomated MIP Images Created Directly on 16-Section Multidetector CT Console for Evaluation of Living Renal Donors
Radiology, August 1, 2007; 244(2): 583 - 590.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Rastogi, D. V. Sahani, M. A. Blake, D. C. Ko, and P. R. Mueller
Evaluation of Living Renal Donors: Accuracy of Three-dimensional 16-Section CT
Radiology, July 1, 2006; 240(1): 136 - 144.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
E. K. Fishman, D. R. Ney, D. G. Heath, F. M. Corl, K. M. Horton, and P. T. Johnson
Volume rendering versus maximum intensity projection in CT angiography: what works best, when, and why.
RadioGraphics, May 1, 2006; 26(3): 905 - 922.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. T. Johnson and E. K. Fishman
IV Contrast Selection for MDCT: Current Thoughts and Practice
Am. J. Roentgenol., February 1, 2006; 186(2): 406 - 415.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
N. C. Dalrymple, S. R. Prasad, M. W. Freckleton, and K. N. Chintapalli
Informatics in Radiology (infoRAD): Introduction to the Language of Three-dimensional Imaging with Multidetector CT
RadioGraphics, September 1, 2005; 25(5): 1409 - 1428.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.