AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chiang, G.
Right arrow Articles by Mehta, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chiang, G.
Right arrow Articles by Mehta, T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2004; 183:725-731
© American Roentgen Ray Society


Obstetric-Gynecologic Imaging

The Intradecidual Sign: Is It Reliable for Diagnosis of Early Intrauterine Pregnancy?

Gloria Chiang1, Deborah Levine2,3, Michelle Swire2, Ann McNamara2 and Tejas Mehta2

1 Harvard Medical School, 25 Shattuck St., Boston, MA 02115.
2 Department of Radiology, Beth Israel Deaconess Medical Center, 330 Brookline Ave., Boston, MA 02215.
3 Department of Obstetrics and Gynecology, Beth Israel Deaconess Medical Center, Boston, MA 02215.

Abstract

OBJECTIVE. Our aim was to determine the accuracy of the intradecidual sign for the diagnosis of intrauterine pregnancy and the exclusion of ectopic pregnancy.

CONCLUSION. The intradecidual sign reliably excludes the presence of an ectopic pregnancy. The sensitivity for diagnosis of an intrauterine pregnancy increases when human chorionic gonadotropin levels are equal to or greater than 2,000 mIU/mL or the mean sac diameter is equal to or greater than 3 mm. It is of utmost importance to visualize this sign on multiple views with an unchanging appearance.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
D. Levine
Ectopic Pregnancy
Radiology, November 1, 2007; 245(2): 385 - 397.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.