AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zhu, X.
Right arrow Articles by Huang, Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zhu, X.
Right arrow Articles by Huang, Z.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2004; 183:809-816
© American Roentgen Ray Society


Chest Imaging

Low-Dose Chest CT: Optimizing Radiation Protection for Patients

Xiaohua Zhu1, Jianqun Yu2 and Zheng Huang3

1 Department of Radiology, Shanghai Pneumology Hospital, Shanghai, People's Republic of China.
2 Department of Radiology, First Affiliated Hospital of Hua-xi Medical Center, West China University of Medical Sciences, Shichuan, People's Republic of China.
3 HealthONE Alliance, 5125 Stapleton Dr. N, Denver, CO 80216.

Abstract

OBJECTIVE. The aim of our study was to evaluate CT scanning protocols to determine how best to minimize patient exposure to ionizing radiation while maintaining sufficient image quality to detect pulmonary diseases.

SUBJECT AND METHODS. The CT dose index (CTDI) was determined by scanning an acrylic phantom at various tube current–time products (7.5–115 mAs). Image quality was evaluated by comparing the homogeneity and noise level of CT scans obtained in the acrylic phantom with those obtained in a water-equivalent phantom. The CT scans obtained at various milliampere-second settings in patients with nodules or diffuse opacifications were assessed. The relationships between the CTDI and the image quality of the CT scans (noise level and artifacts) were established.

RESULTS. The reduction of a conventional tube current–time product (115 mAs) by 65%, 78%, or 93.5% can decrease the CTDI by 60%, 70%, or 85%, respectively. In correlating the image quality of each CT scan to the milliampere-second settings used to obtain it, we found that homogeneity decreased as milliampere-second settings decreased, whereas the noise level increased as milliampere-second settings decreased. For both 8- and 3-mm slice thicknesses, the homogeneity of CT scans acquired at 7.5 mAs or greater was within the acceptable range (< 4 H). However, the noise level of CT scans remained within the acceptable range (< 0.35%) when 25 mAs or greater was used. The evaluation of the image quality of the patients' CT scans indicated no statistical significance in image quality rating between the scans obtained at 25 mAs and those obtained at 115 mAs (p > 0.01).

CONCLUSION. Low-dose (i.e., 40 or 25 mAs) helical chest CT produced satisfactory image quality and reduced the CTDI, thereby maximally protecting patients from radiation exposure.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
T. Kubo, P.-J. P. Lin, W. Stiller, M. Takahashi, H.-U. Kauczor, Y. Ohno, and H. Hatabu
Radiation Dose Reduction in Chest CT: A Review
Am. J. Roentgenol., February 1, 2008; 190(2): 335 - 343.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. D. MacKenzie, J. Nazario-Larrieu, T. Cai, M. S. Ledbetter, M. A. Duran-Mendicuti, P. F. Judy, and F. J. Rybicki
Reduced-Dose CT: Effect on Reader Evaluation in Detection of Pulmonary Embolism
Am. J. Roentgenol., December 1, 2007; 189(6): 1371 - 1379.
[Abstract] [Full Text] [PDF]


Home page
Arch. Dis. Child.Home page
W Mazrani, K McHugh, and P J Marsden
The radiation burden of radiological investigations
Arch. Dis. Child., December 1, 2007; 92(12): 1127 - 1131.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
M. J. Gollub, R. Hong, D. M. Sarasohn, and T. Akhurst
Limitations of CT During PET/CT
J. Nucl. Med., October 1, 2007; 48(10): 1583 - 1591.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Madani, V. De Maertelaer, J. Zanen, and P. A. Gevenois
Pulmonary Emphysema: Radiation Dose and Section Thickness at Multidetector CT Quantification--Comparison with Macroscopic and Microscopic Morphometry
Radiology, April 1, 2007; 243(1): 250 - 257.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
H. Kuehl, P. Veit, S. J. Rosenbaum, A. Bockisch, and G. Antoch
Can PET/CT Replace Separate Diagnostic CT for Cancer Imaging? Optimizing CT Protocols for Imaging Cancers of the Chest and Abdomen
J. Nucl. Med., January 1, 2007; 48(1_suppl): 45S - 57S.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.