AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rizzo, S.
Right arrow Articles by Saini, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Rizzo, S.
Right arrow Articles by Saini, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.04.1513
AJR 2006; 186:673-679
© American Roentgen Ray Society


Clinical Obser vations

Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and Pelvis

Stefania Rizzo1, Mannudeep Kalra1,2, Bernhard Schmidt3, Tejas Dalal1,4, Christoph Suess3, Thomas Flohr3, Michael Blake1 and Sanjay Saini2

1 Department of Radiology, Massachusetts General Hospital, White 270, Boston, MA 02114.
2 Present address: Department of Radiology, Emory University Hospital, 1364 Clifton Rd. NE, Atlanta, GA 30322.
3 Siemens Medical Solutions, Forchheim, Germany.
4 Present address: University of Vermont, Burlington, VT 05405.

Abstract

OBJECTIVE. The objective of our study was to compare image quality and radiation dose associated with abdominopelvic CT using combined modulation, angular modulation, and constant tube current.

CONCLUSION. Compared with using a constant tube current to scan the abdomen and pelvis, the use of a combined modulation technique results in a substantial reduction (42-44%) in radiation dose with acceptable image noise and diagnostic acceptability.

Keywords: abdomen • CT technique • pelvis • radiation dose • tube current modulation


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
M. Brink, F. de Lange, L. J. Oostveen, H. M. Dekker, D. R. Kool, J. Deunk, M. J. R. Edwards, C. van Kuijk, R. L. Kamman, and J. G. Blickman
Arm Raising at Exposure-controlled Multidetector Trauma CT of Thoracoabdominal Region: Higher Image Quality, Lower Radiation Dose
Radiology, November 1, 2008; 249(2): 661 - 670.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. A. Leswick, M. M. Hunt, S. T. Webster, and D. A. Fladeland
Thyroid Shields versus z-Axis Automatic Tube Current Modulation for Dose Reduction at Neck CT
Radiology, November 1, 2008; 249(2): 572 - 580.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
M.T. Russell, J.R. Fink, F. Rebeles, K. Kanal, M. Ramos, and Y. Anzai
Balancing Radiation Dose and Image Quality: Clinical Applications of Neck Volume CT
AJNR Am. J. Neuroradiol., April 1, 2008; 29(4): 727 - 731.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. T. Schindera, R. C. Nelson, T. L. Toth, G. T. Nguyen, G. I. Toncheva, D. M. DeLong, and T. T. Yoshizumi
Effect of Patient Size on Radiation Dose for Abdominal MDCT with Automatic Tube Current Modulation: Phantom Study
Am. J. Roentgenol., February 1, 2008; 190(2): W100 - W105.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
D. D. Cody and M. Mahesh
AAPM/RSNA Physics Tutorials AAPM/RSNA Physics Tutorial for Residents: Technologic Advances in Multidetector CT with a Focus on Cardiac Imaging
RadioGraphics, November 1, 2007; 27(6): 1829 - 1837.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Hur, S. W. Hong, S. Y. Kim, Y. H. Kim, Y. J. Hwang, W. R. Lee, and S. J. Cha
Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography
Am. J. Roentgenol., July 1, 2007; 189(1): 188 - 196.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.