AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hurwitz, L. M.
Right arrow Articles by Barnes, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hurwitz, L. M.
Right arrow Articles by Barnes, L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.04.1915
AJR 2006; 186:871-876
© American Roentgen Ray Society


Original Research

Radiation Dose to the Fetus from Body MDCT During Early Gestation

Lynne M. Hurwitz1, Terry Yoshizumi1,2, Robert E. Reiman1,2, Philip C. Goodman1, Erik K. Paulson1, Donald P. Frush1, Greta Toncheva2, Giao Nguyen2 and Lottie Barnes2

1 Department of Radiology, Duke University Medical Center, DUMC 3808, Durham, NC 27710.
2 Radiation Safety Division, Duke University Health System, Durham, NC 27710.

OBJECTIVE. The purpose of our study was to determine radiation dose to the fetus at early gestation when contemporary MDCT scanners are used for common clinical indications.

MATERIALS AND METHODS. Anthropomorphic phantoms were constructed to reflect a pregnant woman. Thermoluminescence dosimeters (TLDs) and metal oxide semiconductor field effect transistor (MOSFET) detectors were placed in appropriate locations to determine real-time radiation exposure to the fetus at 0 and 3 months' gestation. Imaging was performed on a 16-MDCT scanner using current institutional CT protocols: renal stone (140 kVp, 160 mA, rotation time of 0.5 sec, 16 x 0.625 mm), appendix (140 kVp, 340 mA, rotation time of 0.5 sec, 16 x 0.625 mm), and pulmonary embolus (140 kVp, 380 mA, rotation time of 0.8 sec, 16 x 1.25 mm).

RESULTS. The radiation dose to the fetus at 0 and 3 months, respectively, was as follows: renal stone protocol, 0.8–1.2 and 0.4–0.7 cGy; appendix protocol, 1.52–1.68 and 2–4 cGy; and pulmonary embolus protocol, 0.024–0.047 and 0.061–0.066 cGy.

CONCLUSION. Radiation doses to the fetus from institutional MDCT protocols that may be used during pregnancy (for pulmonary embolus, appendicitis, and renal colic) are below the level thought to induce neurologic detriment to the fetus. Imaging the mother for appendicitis theoretically may double the fetal risk for developing a childhood cancer. Radiation doses to the fetus from pulmonary embolus chest CT angiography are of the same magnitude as ventilation–perfusion (V/Q) scanning.

Keywords: CT • fetal imaging • radiation dose • women's imaging


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
S. Kim, T. T. Yoshizumi, G. Toncheva, S. Yoo, and F.-F. Yin
COMPARISON OF RADIATION DOSES BETWEEN CONE BEAM CT AND MULTI DETECTOR CT: TLD MEASUREMENTS
Radiat Prot Dosimetry, December 13, 2008; (2008) ncn305v1.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Angel, C. V. Wellnitz, M. M. Goodsitt, N. Yaghmai, J. J. DeMarco, C. H. Cagnon, J. W. Sayre, D. D. Cody, D. M. Stevens, A. N. Primak, et al.
Radiation Dose to the Fetus for Pregnant Patients Undergoing Multidetector CT Imaging: Monte Carlo Simulations Estimating Fetal Dose for a Range of Gestational Age and Patient Size
Radiology, October 1, 2008; 249(1): 220 - 227.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
S K DOSHI, I S NEGUS, and J M ODUKO
Fetal radiation dose from CT pulmonary angiography in late pregnancy: a phantom study
Br. J. Radiol., August 1, 2008; 81(968): 653 - 658.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
G R IBALL, E V KENNEDY, and D S BRETTLE
Modelling the effect of lead and other materials for shielding of the fetus in CT pulmonary angiography
Br. J. Radiol., June 1, 2008; 81(966): 499 - 503.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
M. A. Lichtman
Is There an Entity of Chemically Induced BCR-ABL-Positive Chronic Myelogenous Leukemia?
Oncologist, June 1, 2008; 13(6): 645 - 654.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
J. Glassroth
Evaluation of Suspected Pulmonary Embolism During Pregnancy--Reply
JAMA, April 9, 2008; 299(14): 1665 - 1666.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, T. T. Yoshizumi, G. I. Toncheva, G. Nguyen, L. M. Hurwitz, and R. C. Nelson
Early First-Trimester Fetal Radiation Dose Estimation in 16-MDCT Without and With Automated Tube Current Modulation
Am. J. Roentgenol., April 1, 2008; 190(4): 860 - 864.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. K. Paulson, C. Weaver, L. M. Ho, L. Martin, J. Li, J. Darsie, and D. P. Frush
Conventional and Reduced Radiation Dose of 16-MDCT for Detection of Nephrolithiasis and Ureterolithiasis
Am. J. Roentgenol., January 1, 2008; 190(1): 151 - 157.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. T. Schindera, R. C. Nelson, S. Mukundan Jr, E. K. Paulson, T. A. Jaffe, C. M. Miller, D. M. DeLong, K. Kawaji, T. T. Yoshizumi, and E. Samei
Hypervascular Liver Tumors: Low Tube Voltage, High Tube Current Multi Detector Row CT for Enhanced Detection Phantom Study
Radiology, December 1, 2007; 246(1): 125 - 132.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, A. M. Gaca, S. Delaney, T. T. Yoshizumi, G. Toncheva, G. Nguyen, and D. P. Frush
Radiation Doses from Small-Bowel Follow-Through and Abdominopelvic MDCT in Crohn's Disease
Am. J. Roentgenol., November 1, 2007; 189(5): 1015 - 1022.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, C. M. Miller, and E. M. Merkle
Practice Patterns in Imaging of the Pregnant Patient with Abdominal Pain: A Survey of Academic Centers
Am. J. Roentgenol., November 1, 2007; 189(5): 1128 - 1134.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Remy-Jardin, M. Pistolesi, L. R. Goodman, W. B. Gefter, A. Gottschalk, J. R. Mayo, and H. D. Sostman
Management of Suspected Acute Pulmonary Embolism in the Era of CT Angiography: A Statement from the Fleischner Society
Radiology, November 1, 2007; 245(2): 315 - 329.
[Full Text] [PDF]


Home page
RadioGraphicsHome page
S. J. Patel, D. L. Reede, D. S. Katz, R. Subramaniam, and J. K. Amorosa
Imaging the Pregnant Patient for Nonobstetric Conditions: Algorithms and Radiation Dose Considerations
RadioGraphics, November 1, 2007; 27(6): 1705 - 1722.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E V Kennedy, G R Iball, and D S Brettle
Investigation into the effects of lead shielding for fetal dose reduction in CT pulmonary angiography
Br. J. Radiol., August 1, 2007; 80(956): 631 - 638.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. L. Hollingsworth, T. T. Yoshizumi, D. P. Frush, F. P. Chan, G. Toncheva, G. Nguyen, C. R. Lowry, and L. M. Hurwitz
Pediatric Cardiac-Gated CT Angiography: Assessment of Radiation Dose
Am. J. Roentgenol., July 1, 2007; 189(1): 12 - 18.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
C. H. McCollough, B. A. Schueler, T. D. Atwell, N. N. Braun, D. M. Regner, D. L. Brown, and A. J. LeRoy
Radiation Exposure and Pregnancy: When Should We Be Concerned?
RadioGraphics, July 1, 2007; 27(4): 909 - 917.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. T. Yoshizumi, P. C. Goodman, D. P. Frush, G. Nguyen, G. Toncheva, M. Sarder, and L. Barnes
Validation of Metal Oxide Semiconductor Field Effect Transistor Technology for Organ Dose Assessment During CT: Comparison with Thermoluminescent Dosimetry
Am. J. Roentgenol., May 1, 2007; 188(5): 1332 - 1336.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
D. S. Katz, V. Merunka, J. J. Hines, E. M. Meiner, I. Pedrosa, D. Levine, and N. M. Rofsky
Invited Commentary * Authors' Response
RadioGraphics, May 1, 2007; 27(3): 743 - 753.
[Full Text] [PDF]


Home page
RadiologyHome page
P. D. Stein, P. K. Woodard, J. G. Weg, T. W. Wakefield, V. F. Tapson, H. D. Sostman, T. A. Sos, D. A. Quinn, K. V. Leeper Jr, R. D. Hull, et al.
Diagnostic Pathways in Acute Pulmonary Embolism: Recommendations of the PIOPED II Investigators
Radiology, January 1, 2007; 242(1): 15 - 21.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.