AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by de Monyé, C.
Right arrow Articles by van der Lugt, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by de Monyé, C.
Right arrow Articles by van der Lugt, A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.05.0143
AJR 2006; 186:1737-1745
© American Roentgen Ray Society


Original Research

Optimization of CT Angiography of the Carotid Artery with a 16-MDCT Scanner: Craniocaudal Scan Direction Reduces Contrast Material-Related Perivenous Artifacts

Cécile de Monyé1, Thomas T. de Weert1, William Zaalberg1, Filippo Cademartiri1, Dorine A. M. Siepman2, Diederik W. J. Dippel2 and Aad van der Lugt1

1 Department of Radiology, Erasmus University Medical Center, Dr. Molewaterplein 40, Rotterdam, The Netherlands, 3015 GD.
2 Department of Neurology, Erasmus University Medical Center, Rotterdam, The Netherlands.

OBJECTIVE. The objective of our study was to compare the effect of a caudocranial scan direction versus a craniocaudal scan direction on arterial enhancement and perivenous artifacts in 16-MDCT angiography of the supraaortic arteries.

SUBJECTS AND METHODS. Eighty consecutive patients (51 men; mean age, 62 years; age range, 28-89 years) underwent scanning in the caudocranial direction (group 1; n = 40) or the craniocaudal direction (group 2; n = 40). All patients received 80 mL of contrast material followed by a 40-mL saline chaser bolus, both administered IV at 4 mL/sec. Bolus tracking was used. Attenuation inside the arterial lumen was measured at intervals of 1 sec throughout the data set. Attenuation in the superior vena cava (SVC) was measured. Contrast material-related perivenous artifacts were graded on a scale of 0-3 (none to extensive).

RESULTS. Attenuation in the ascending aorta, carotid bifurcation, and intracranial arteries was slightly lower in group 2 versus group 1 (231 ± 64 H, 348 ± 52 H, and 258 ± 48 H vs 282 ± 43 H, 381 ± 73 H, and 291 ± 77 H, respectively; p < 0.05). Maximum and mean arterial attenuations were slightly lower in group 2 versus group 1 (369 ± 58 H and 303 ± 48 H vs 401 ± 71 H and 334 ± 58 H; p < 0.05). Attenuation in the SVC was much lower in group 2 versus group 1 (169 ± 39 H vs 783 ± 330 H; p < 0.001). Mean streak artifact score was much lower in group 2 versus group 1 (1.3 ± 0.9 vs 2.5 ± 0.6; p < 0.001).

CONCLUSION. Use of a craniocaudal scan direction results in slightly lower attenuation of the carotid artery and much lower attenuation of the SVC. Streak artifacts are significantly reduced. This technique allows better evaluation of the ascending aorta and supraaortic arteries.

Keywords: arteries • cardiovascular disease • cardiovascular imaging • CT angiography • CT technique • perivenous artifacts


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2006 by the American Roentgen Ray Society.