OBJECTIVE. The objective of this article is to describe a protocol for the administration of ß-blockers for cardiac CT. A low and regular heart rate is necessary for optimal visualization of the coronary arteries on CT and can be achieved by the administration of medications.
CONCLUSION. Beta-blockers can be safely given, orally or IV, to most patients to lower the heart rate for cardiac CT. A protocol can be implemented and patients can be screened for certain contraindications to allow successful administration of these medications by radiologists.
Keywords: ß-blocker cardiac imaging coronary arteries CT arteriography MDCT
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
S. Leschka, H. Scheffel, L. Husmann, O. Gamperli, B. Marincek, P. A. Kaufmann, and H. Alkadhi Effect of Decrease in Heart Rate Variability on the Diagnostic Accuracy of 64-MDCT Coronary Angiography Am. J. Roentgenol., June 1, 2008; 190(6): 1583 - 1590. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Colletti Coronary CT Angiography Without {beta}-Blockers Am. J. Roentgenol., December 1, 2007; 189(6): 1324 - 1325. [Full Text] [PDF] |
||||
![]() |
D. Matt, H. Scheffel, S. Leschka, T. G. Flohr, B. Marincek, P. A. Kaufmann, and H. Alkadhi Dual-Source CT Coronary Angiography: Image Quality, Mean Heart Rate, and Heart Rate Variability Am. J. Roentgenol., September 1, 2007; 189(3): 567 - 573. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Mahesh and D. D. Cody AAPM/RSNA Physics Tutorial for Residents: Physics of Cardiac Imaging with Multiple-Row Detector CT RadioGraphics, September 1, 2007; 27(5): 1495 - 1509. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Hur, S. W. Hong, S. Y. Kim, Y. H. Kim, Y. J. Hwang, W. R. Lee, and S. J. Cha Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography Am. J. Roentgenol., July 1, 2007; 189(1): 188 - 196. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. M. Colletti Cardiac Imaging 2006 Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S337 - S340. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |