AJR Get Involved! Great Benefits! Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Google Scholar
Right arrow Articles by Konen, E.
Right arrow Articles by Di-Segni, E.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Konen, E.
Right arrow Articles by Di-Segni, E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
DOI:10.2214/AJR.07.2951
AJR 2008; 191:26-31
© American Roentgen Ray Society


Original Research

The Role of ECG-Gated MDCT in the Evaluation of Aortic and Mitral Mechanical Valves: Initial Experience

Eli Konen1, Orly Goitein1, Micha S. Feinberg2, Yael Eshet1, Ehud Raanani3, Uri Rimon1 and Elio Di-Segni1,2

1 Department of Diagnostic Imaging, Sheba Medical Center, Tel Hashomer, Ramat Gan 52621, Israel.
2 Heart Institute, Sheba Medical Center, Ramat Gan, Israel.
3 Department of Cardiac Surgery, Sheba Medical Center, Ramat Gan, Israel.

OBJECTIVE. The objective of our study was to evaluate the role of ECG-gated MDCT in the functional evaluation of mechanical prosthetic aortic and mitral valves.

MATERIALS AND METHODS. Twenty sequential patients with 23 mechanical prosthetic valves were evaluated with an ECG-gated 40- or 64-MDCT scanner. Multiplanar reformation, maximal-intensity-projection, volume-rendering, and volume-averaging techniques were used for visualization of valve leaflets in systole and diastole. The visibility of each mechanical valve was evaluated by consensus of a radiologist and a cardiologist using a subjective 5-point scale (0–4). MDCT findings were correlated with fluoroscopic opening and closing angle measurements and echocardiographic pressure gradient measurements in 11 and 19 valves, respectively.

RESULTS. The series included 18 bileaflet and five single-leaflet mechanical valves. The visibility score for the bileaflet mechanical valves was excellent (score of 4) in all 18 cases, but it was lower for single-leaflet valves (mean score, 2.8; range, 1–4) (p = 0.04). Bland-Altman plots showed high agreement between MDCT and fluoroscopy for measurements of opening and closing angles of bileaflet mechanical valves. In four patients, a stuck valve was seen on MDCT and was confirmed by fluoroscopy. Doppler echocardiography showed increased transvalvular pressure in two of the four patients with a stuck mitral valve and increased transaortic pressure in four patients with normal prosthetic aortic valve motion.

CONCLUSION. Our preliminary results suggest that MDCT is a promising technique for functional evaluation of bileaflet mechanical valves, allowing reliable measurements of opening and closing leaflet angles. However, the role of MDCT in the evaluation of single-leaflet valves might be limited.

Keywords: aortic valve • cardiac imaging • MDCT • mitral valve • prosthetic valves