AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohnen, M.
Right arrow Articles by Moedder, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohnen, M.
Right arrow Articles by Moedder, U.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2004; 183:1355-1359
© American Roentgen Ray Society

Feasibility of MDCT Colonography in Ultra-Low-Dose Technique in the Detection of Colorectal Lesions: Comparison with High-Resolution Video Colonoscopy

Mathias Cohnen1, Christoph Vogt2, Andreas Beck3, Kjel Andersen1, Wolfram Heinen1, Stephan vom Dahl2, Volker Aurich3, Dieter Haeussinger2 and Ulrich Moedder1

1 Institute of Diagnostic Radiology, University Hospital Duesseldorf, MNR-Klinik, Moorenstrasse 5, Duesseldorf 40225, Germany.
2 Department of Gastroenterology, Hepatology, and Infectious Diseases, University Hospital Duesseldorf, Duesseldorf, Germany.
3 Institute of Informatics, Heinrich-Heine-University, Duesseldorf, Germany.

Received February 10, 2004; accepted after revision April 15, 2004.

 
Address correspondence to M. Cohnen (cohnen{at}med.uni-duesseldorf.de).


Abstract
Top
Abstract
Introduction
Subjects and Methods
Results
Discussion
References
 
OBJECTIVE. The purpose of this study was to assess the feasibility of MDCT colonography in an ultra-low-dose technique in the detection of endoluminal colonic lesions compared with high-resolution video colonoscopy.

SUBJECTS AND METHODS. After standard bowel cleansing, 137 patients (77 men, 60 women; mean [± SD] age, 57.1 ± 11.3 years) underwent high-resolution video colonoscopy within 2 hr after ultra-low-dose MDCT colonography had been performed. Ultra-low-dose MDCT colonography was performed with patients in the supine position only using 10 mAs (effective weighted CT dose index, 0.94 mGy). After mathematic noise reduction by nonlinear gaussian filter chains, using dedicated software (ECCET), images were analyzed by two blinded observers in simultaneously displayed interactive 2D and 3D modes. Findings of ultra-low-dose MDCT colonography were compared with the results obtained with high-resolution video colonoscopy.

RESULTS. Calculated effective doses were 0.7 and 1.2 mSv for men and women, respectively. Ultra-low-dose MDCT colonography detected 84 (62%) of 135 lesions: 11 (78.6%) of 14 large polyps (> 10 mm), 12 (85.7%) of 14 medium polyps (9.9-5 mm), and 61 (57%) of 107 small polyps (< 5 mm). On a patient-by-patient basis, an overall sensitivity of 70.3% with a specificity of 80.8% was calculated. False-positive findings were seen mostly for small lesions (eight medium and 29 small lesions). Two of the three false-negative lesions were retrospectively detected in contrast-enhanced cleansing fluid; one was a flat lipoma not detectable on ultra-low-dose MDCT colonography.

CONCLUSION. Despite an effective dose of approximately 1 mSv, MDCT colonography using an ultra-low-dose technique performs as well as MDCT colonography with a standard dose, according to published data. After mathematic noise reduction, 82% of polyps larger than 5 mm can be detected.


Introduction
Top
Abstract
Introduction
Subjects and Methods
Results
Discussion
References
 
MDCT has improved virtual imaging techniques. In comparison to single-slice helical CT, MDCT colonography—with an increased resolution in the z-axis direction due to thinner slice collimation and better volume coverage—potentially increases the number of lesions detected in virtual colonoscopy [1-3]. In an experimental setting, this effect was found to be more pronounced in 16-MDCT than in 4-MDCT [4, 5]. Because of the reduced examination time and breath-hold period, fewer respiratory artifacts and an improved colonic distention are noted [6]. The main disadvantage of CT remains the use of ionizing radiation. This topic becomes of particular interest when CT colonography is proposed as a potential screening tool in the prevention of colorectal cancer. Therefore, first attempts have been made to decrease patient exposure, mainly by modification of technical parameters [7-9]. In view of the inherently high contrast between the air-filled lumen of the colon and the soft-tissue attenuation of the colonic wall, a relevant dose reduction should be achievable without loss of diagnostic accuracy.

Therefore, this study was performed to assess the sensitivity and specificity of MDCT colonography in the ultra-low-dose technique in comparison to the gold standard, high-resolution video colonoscopy.


Subjects and Methods
Top
Abstract
Introduction
Subjects and Methods
Results
Discussion
References
 
One hundred thirty-seven patients (77 men, 60 women; mean (± SD) age, 57.1 ± 11.3 years) were prospectively examined with the ultra-low-dose technique on MDCT colonography. All patients were recruited at the outpatient clinic and were referred for colonoscopic workup because of abdominal complaints including changing bowel habits (n = 31, 22.6%), abdominal pain (n = 43, 31.4%), or heme-positive stools (n = 26, 19%). Thirty-seven patients (27%) underwent control colonoscopy after previous polypectomy. None of the patients was previously known to have a tumor or relatives with colorectal cancer. All patients gave written informed consent after the study was approved by the local ethics committee.

Ultra-low-dose MDCT colonography was performed using a Somatom Plus 4 Volume Zoom scanner (Siemens Medical Solutions) after a standard oral colonic preparation starting on the day before the examination using bisacodyl (Prepacol, Guerbet) combined with a liquid diet of 4-5 L of a polyethylene glycolelectrolyte solution (Endofalk, Falk Pharma).

After careful digital rectal examination, insufflation of room air into the colon was achieved by the patients themselves using an air bulb to the subjective maximum tolerance. During this procedure, the patient was advised to turn from a left-sided to a prone position and further to a right-sided position to facilitate homogeneous bowel distention. Colonic distention was assessed on the digital topogram. When necessary, further air insufflation was performed. No IV medication was given. Examinations were performed in the supine position only.

Patients were instructed to slowly exhale if they could not maintain the entire breath-hold. Breath-hold time ranged between 20 and 30 sec. Total radiation exposure was calculated with a commercially available software package (CTExpo version 1.3, G. Stamm and H.D. Nagel) [10]. This software package calculates effective doses according to International Commission on Radiological Protection 60 [11] using the respective tissue-weighting factors. Estimated effective doses both for men and women were reported using conversion factors for the abdomen.

Scanning parameters were as follows: detector collimation was 4 x 1 mm; reconstructed slice width was 1.25 mm with a reconstruction increment of 0.7 mm. Scanning was performed with an 8-mm table feed accounting for a pitch of 8 (or 2 in classical terms). The rotation time was 0.5 sec with 120 kVp. The tube current was set at the lowest milliampere setting possible: 10 effective mAs corresponding to 40 electric mA resulted in an effective weighted CT dose index of 1.14 mGy as indicated by the implemented CT software.

After transfer to a remote double PC-based workstation, the reconstructed images underwent a mathematic noise-reduction algorithm using edge-preserving nonlinear gaussian filter chains [12] (Figs. 1A, 1B). Dedicated software (ECCET, www.eccet.de), which was developed by our Department of Informatics, segments colonic lumen automatically using a threshold of -750 H and generates a 3D volume. ECCET allows a simultaneous visualization of 2D multiplanar reconstructions and high-resolution interactive real-time 3D views and has the ability to switch directly between 2D and 3D mode.



View larger version (50K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 1A. Sagittal 2D reformation of ultra-low-close MDCT of abdomen showing descending colon to demonstrate effect of mathematic noise filter (edge-preserving nonlinear gaussian filter chains). Images show nearly complete reduction of mottle or noise (A) with persistent sharp bowel wall (B).

 


View larger version (27K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 1B. Sagittal 2D reformation of ultra-low-close MDCT of abdomen showing descending colon to demonstrate effect of mathematic noise filter (edge-preserving nonlinear gaussian filter chains). Images show nearly complete reduction of mottle or noise (A) with persistent sharp bowel wall (B).

 

Ultra-low-dose MDCT colonographs were interpreted by an experienced radiologist as well as one gastroenterologist. Any observed lesion was classified as tumor, polyp, or residual stool by consensus, and size and segmental location were recorded. Lesion size was determined using electronic caliper measurements in 3D images, and location of lesions was attributed to eight colonic segments (cecum, ascending colon, right flexure, transverse colon, left flexure, descending and sigmoid colon, and rectum). All classified lesions were compared with the findings of high-resolution video colonoscopy regarding location (same or adjacent segments) and size (estimated size, ± 2 mm). Concerning size, three groups were differentiated: large polyps 10 mm or more, medium polyps 9.9-5 mm, and small polyps less than 5 mm in diameter.

Colonic dilatation was regarded as optimal when all or all but one segment were well expanded. Moderate dilatation was defined as occurring when dilatation was suboptimal in two or more segments; a collapse of one or more segments was regarded as insufficient. Residual stool or fluid was noted as well as noise-related artifacts.

High-resolution video colonoscopy—considered the gold standard—was performed by an experienced endoscopic gastroenterologist using the standard technique directly after ultra-low-dose MDCT colonography. Video colonography was performed using a high-resolution endoscope, processor, and light source (Olympus Evis Exera 160 Line, PCF-Q160AL Endoscope) with the patient under conscious sedation with midazolam and propofol. All tumors or polyps were photodocumented, and their size was assessed relative to an opened biopsy forceps. Positioning in the colon material for a histolopathologic examination was possible in 98% of lesions because either resection by biopsy or removal by snare polypectomy was done. Both the endoscopist and the ultra-low-dose MDCT colonography observers were blinded to each other's results.

Cross-table analysis, including Spearman's rank correlation test as well as statistical evaluation using the Student's t test and Wilcoxon's signed rank test at a significance level of 0.05, was performed using commercially available software (SPSS version 11.0 [Statistical Package for the Social Sciences] for Windows [Microsoft]).


Results
Top
Abstract
Introduction
Subjects and Methods
Results
Discussion
References
 
Ultra-low-dose MDCT colonography was performed in all patients without complications. The average examination time in the CT suite was 10 min (range, 8-12 min). Data transfer (3-5 min); fully automated preparation, including noise reduction and segmentation (25 min); and interactive interpretation by two observers (10-20 min) took, on average, 40-50 min.

Colonic distention was regarded as optimal or moderate in 97.2% of patients. Residual stool was found in 15 patients examined with ultra-low-dose MDCT colonography. Residual fluid was seen to a moderate degree in one third of patients, although a large amount of cleansing fluid was noted in 15.1% of colonic segments, obscuring more than one third of the colonic surface, mostly in the ascending colon and the descending colon. Noise-related artifacts were mostly observed in the pelvic region: 20.2% of patients with ultra-low-dose MDCT colonography showed endoluminal "snow" artifacts. When the threshold of -750 H was increased to -650 H, these artifacts were greatly diminished and nonvisible without loss of diagnostic confidence.

Calculation of the effective dose is based on the effective weighted CT dose index. For an entire MDCT scan of the abdomen with an approximately 400-mm scanned length, an effective dose of approximately 0.7 mSv for men and 1 mSv for women, respectively, has to be expected.

Table 1 gives detailed results concerning tumors and polyps. Overall, 84 (62%) of 135 lesions were seen on ultra-low-dose MDCT colonography. Detailed analysis reveals that in ultra-low-dose MDCT colonography, 11 (78.6%) of 14 large lesions were seen, although 12 of 14 medium polyps and 61 of 107 small polyps were detected as compared with high-resolution video colonoscopy, accounting for a sensitivity of 85.7% for medium-sized and 57% for small polyps, respectively (Table 1 and Figs. 2A, 2B). Spearman's correlation coefficient for ultra-low-dose MDCT colonography versus high-resolution video colonoscopy was 0.87 for large lesions, 0.62 for medium lesions, and 0.5 for small lesions, with a significance level of p < 0.001 (Figs. 3A, 3B).


View this table:
[in this window]
[in a new window]

 
TABLE 1 Performance Measures for MDCT Colonography in Study Population

 


View larger version (124K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 2A. 52-year-old man with known cirrhosis of liver and heme-positive stools. Medium (8-mm) polyp in sigmoid colon located between two haustral folds. Although these are better separated during conventional colonscopy (A), polyp can be well appreciated on ultra-low-dose MDCT colonography (arrow, B).

 


View larger version (107K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 2B. 52-year-old man with known cirrhosis of liver and heme-positive stools. Medium (8-mm) polyp in sigmoid colon located between two haustral folds. Although these are better separated during conventional colonscopy (A), polyp can be well appreciated on ultra-low-dose MDCT colonography (arrow, B).

 


View larger version (148K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 3A. 75-year-old man with known diverticulosis and recurrent left lower quadrant pain. Small (3-mm) polypoid lesion in ascending colon located on haustral fold is seen on high-resolution video colonoscopy (A) and ultra-low-dose MDCT colonography (B). MDCT colonography showed multiple diverticula of sigmoid colon without sign of acute inflammation (not shown).

 


View larger version (129K):
[in this window]
[in a new window]
[as a PowerPoint slide]
 
Fig. 3B. 75-year-old man with known diverticulosis and recurrent left lower quadrant pain. Small (3-mm) polypoid lesion in ascending colon located on haustral fold is seen on high-resolution video colonoscopy (A) and ultra-low-dose MDCT colonography (B). MDCT colonography showed multiple diverticula of sigmoid colon without sign of acute inflammation (not shown).

 

Overall, the negative predictive value of ultra-low-dose MDCT colonography was 75.6% and the positive predictive value was 76.3%. Fourteen patients with false-positive findings on ultra-low-dose MDCT colonography would have undergone high-resolution video colonoscopy unnecessarily. However, 19 patients with false-negative findings would not have undergone colonoscopy, which includes five patients with false-negative findings for lesions 5 mm or larger.

For lesions of 5 mm or larger, sensitivity of ultra-low-dose MDCT colonography per polyp was 82.1%. On a per-patient basis, sensitivity, specificity, and positive and negative predictive values were 86.3%, 93%, 70.4%, and 97.2%, respectively.


Discussion
Top
Abstract
Introduction
Subjects and Methods
Results
Discussion
References
 
Virtual CT colonography has high potential for the detection of endoluminal polyps and colonic tumors in both symptomatic and asymptomatic patients [1, 13, 14]. It is a noninvasive method without complications and with less patient discomfort than other methods [15].

Our study confirms first-published results showing a high sensitivity and specificity of ultra-low-dose MDCT colonography for large and medium polyps [7, 9, 16]. The sensitivity for polyps 5 mm or larger was 82.1%. On a per-patient basis, sensitivity and specificity were 86.3% and 97.2%. These data show that ultra-low-dose MDCT colonography delineates polyps with a sensitivity and specificity comparable to those of the standard-dose technique as previously published [1, 3, 12, 17-20]. A large meta-analysis recently showed that, on average, CT colonography has a sensitivity of 81% (range, 79-82%) for the detection of polyps 1 cm or more in size (per-polyp basis), combined with a high specificity of 95% [20]. These data decreased to a sensitivity of 62% for polyps 6-9 mm and 43% for polyps smaller than 5 mm. On average, pooled data show a sensitivity and specificity of 88% and 81%, respectively, on CT colonography in patients with a polyp 1 cm or more on a per-patient basis [21].

Positive and negative predictive values of approximately 75% in our study indicate that—if ultra-low-dose MDCT colonography had been used as the only examination—four patients (10.2%) would have undergone conventional colonoscopy unnecessarily and 19 others (13.9%) would not have been sent for high-resolution video colonoscopy, although a polyp was present. These figures include three patients with polyps 5 mm or larger who would have been missed. For medium polyps 5 mm and larger, the negative predictive value of ultra-low-dose MDCT colonography was 97.2%, which would be acceptable even in a screening situation.

The false-negative rate, especially for the large polyps, needs further explanation: Two pedunculated polyps 12 and 14 mm in diameter removed by colonoscopy could not be detected either on 2D or on 3D virtual endoscopic views, even on meticulous retrospective analysis. The most likely reason was the residual fluid found in the colonic segments in which these polyps were found on high-resolution video colonoscopy. One other polyp turned out to consist of a thin lipoma of 15 mm in diameter with a height of not more than 5 mm in the cecal pole that could not be seen on ultra-low-dose MDCT colonography despite adequate distention without residual fluid. Most likely, it could not be differentiated from the abdominal fat surrounding the bowel. The two medium polyps not seen prospectively on ultra-low-dose MDCT colonography were located in the sigmoid colon, which was only moderately distended in one patient and partially collapsed in the other.

As has been reported, observer-independent factors are important: inadequate bowel preparation with residual stool or cleansing fluid and improper colonic distention are critical factors [3]. The IV application of bowel relaxants does not improve colonic distention on MDCT colonography [22, 23]. However, dual positioning of the patient was found to improve bowel-wall conspicuity and the detection rate of endoluminal lesions [22, 24, 25]. The aim of this study was to assess the ultra-low-dose technique with the least possible effective dose. Therefore, double scanning was not intended. However, because possible sequelae of radiation exposure must be weighed against the drawback of missing polyps of a relevant size, dual positioning should be used in a screening situation in cases of moderate or large amounts of residual fluid. In addition to dual positioning, a different approach would be to use oral contrast material to allow electronic subtraction of residual cleansing fluid [26, 27]. Future work will be directed to this approach.

The first large trial to examine virtual CT colonography as a screening technique in direct comparison with conventional colonoscopy yielded excellent results, with sensitivity and specificity exceeding 90% for polyps 6 mm or more [28]. However, if virtual CT colonography should become part of a screening program to reduce mortality rates from colorectal cancer, a reduction in effective dose compared with standard CT examinations is unavoidable. If patients are scanned in both positions, a mean effective dose of 10 mSv or more for the scanner type used in this study is to be expected. The low-dose technique leads to an increase in image noise because the amount of photons reaching the detector is diminished [29]. This increase may deteriorate lesion conspicuity in terms of detectability on low-contrast imaging. The imaging of high-contrast structures allows a higher noise level with a satisfactory image quality and diagnostic reliability [30]. Thus, it seemed feasible to decrease the dose in virtual CT colonography even to an effective dose of approximately 1 mSv because endoluminal lesions show an inherently high contrast to the surrounding colonic air or gas. Because subjectively perceived noise is inversely related to window width, image analysis was done with a wide window center and setting [31]. After application of the mathematic filter algorithm, no relevant noise-related artifacts were noted on 3D renderings of the colonic surface [12].

In addition to false-negative results, virtual colonoscopy is known to produce false-positive results, especially for smaller lesions [1, 3, 13]. This was true for our study as well. The number of false-positive findings was invertedly correlated to size, with a total of 29 false-positive small lesions. These were most likely due to fecal residue. However, one of eight medium false-positive lesions clearly identified as air-free pedunculated lesions on ultra-low-dose MDCT colonography was not found on high-resolution video colonoscopy. Because conventional colonoscopy may have miss rates of more than 20%, some "false-positive" findings on MDCT colonography may represent false-negative findings on high-resolution video colonoscopy [32, 33]. To solve this problem, a repeat colonoscopy (back-to-back) should be performed immediately in the same patient, especially after discordant findings are noted between ultra-low-dose MDCT colonography and high-resolution video colonoscopy.

Limitations of our study include that the examination was performed in only one position, the use of a cleansing agent without contrast medium, and the lack of repeat colonoscopy to exclude false-negative findings in high-resolution video colonoscopy. Furthermore, the data shown cannot be transferred to a screening situation because we did not clinically examine not apparently healthy persons. One hundred thirty-five lesions were found in 54 (39.4%) of 137 patients, resulting in a higher than expected incidence for a screening situation [34, 35]. Furthermore, we did not observe any malignant lesions in the study group undergoing ultra-low-dose MDCT colonography, so that the feasibility in this regard cannot be evaluated. Last, extracolonic disease cannot reliably be assessed so that incidental findings may be missed [36-38]. In our study population, however, one abdominal aortic aneurysm and a right-sided ureteric stone were found and altered the subsequent patient treatment. In cases of suspected or known cancer, a standard-dose abdominal CT examination with IV contrast medium is mandatory to exclude lymphadenopathy or organ metastases.

In conclusion, ultra-low-dose MDCT colonography seems to be feasible as an examination to detect lesions in the lumen of the colon with a high negative predictive value for lesions of 5 mm or more. Performance may be improved by fecal and fluid tagging, potentially minimizing false-negative and false-positive findings. Therefore, MDCT colonography in a low-dose technique may play a significant role in screening for colorectal cancer because radiation exposure is minimized.


References
Top
Abstract
Introduction
Subjects and Methods
Results
Discussion
References
 

  1. Munikrishnan V, Gillams AR, Lees WR, Vaizey CJ, Boulos PB. Prospective study comparing multislice CT colonography with colonoscopy in the detection of colorectal cancer and polyps. Dis Colon Rectum 2003;46:1384 -1390[Medline]
  2. Rottgen R, Schroder RJ, Lorenz M, et al. CT-colonography with the 16-slice CT for the diagnostic evaluation of colorectal neoplasms and inflammatory colon diseases [in German]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr2003; 175:1384 -1391[Medline]
  3. Wessling J, Fischbach R, Domagk D, Lugering N, Neumann E, Heindel W. Colorectal polyps: detection with multislice CT colonography [in German]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr2001; 173:1069 -1071[Medline]
  4. Laghi A, Iannaccone R, Mangiapane F, Piacentini F, Iori S, Passariello R. Experimental colonic phantom for the evaluation of the optimal scanning technique for CT colonography using a multidetector spiral CT equipment. Eur Radiol2003; 13:459 -466[Medline]
  5. Wessling J, Fischbach R, Meier N, et al. CT colonography: protocol optimization with multidetector row CT—study in an anthropomorphic colon phantom. Radiology2003; 228:753 -759[Abstract/Free Full Text]
  6. Hara AK, Johnson CD, MacCarty RL, Welch TJ, McCollough CH, Harmsen WS. CT colonography: single-versus multidetector row imaging. Radiology2001; 219:461 -465[Abstract/Free Full Text]
  7. Cohnen M, Vogt C, Aurich V, Beck A, Haussinger D, Modder U. Multislice CT-colonography in low-dose technique: preliminary results [in German]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 2002;174:835 -838[Medline]
  8. van Gelder RE, Venema HW, Serlie IW, et al. CT colonography at different radiation dose levels: feasibility of dose reduction. Radiology2002; 224:25 -33[Abstract/Free Full Text]
  9. Iannaccone R, Laghi A, Catalano C, Mangiapane F, Piacentini F, Passariello R. Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience. Eur Radiol 2003;13:1297 -1302[Medline]
  10. Stamm G, Nagel HD. CT-expo: a novel program for dose evaluation in CT [in German]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 2002;174:1570 -1576[Medline]
  11. International Commission on Radiological Protection. Summary of recommendations—ICRP 60 Bethesda, MD: International Commission on Radiological Protection, 1990, Report 60
  12. Aurich V, Winkler G, Hahn K, Martin A, Rodenacker K. Noise reduction in images: some recent edge-preserving methods. Pattern Recognition and Image Analysis1999; 9:749 -766
  13. Fenlon HM, Nunes DP, Schroy PC 3rd, Barish MA, Clarke PD, Ferrucci JT. A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps. N Engl J Med1999; 341:1496 -1503[Abstract/Free Full Text]
  14. Ferrucci JT. Colon cancer screening with virtual colonoscopy: promise, polyps, politics. AJR2001; 177:975 -988[Free Full Text]
  15. Taylor SA, Halligan S, Saunders BP, Bassett P, Vance M, Bartram CI. Acceptance by patients of multidetector CT colonography compared with barium enema examinations, flexible sigmoidoscopy, and colonoscopy. AJR 2003;181:913 -921[Abstract/Free Full Text]
  16. Macari M, Bini EJ, Xue X, et al. Colorectal neoplasms: prospective comparison of thin-section low-dose multidetector row CT colonography and conventional colonoscopy for detection. Radiology2002; 224:383 -392[Abstract/Free Full Text]
  17. Bruzzi JF, Moss AC, Fenlon HM. Clinical results of virtual colonoscopy. Eur Radiol2001; 11:2188 -2194[Medline]
  18. Gluecker T, Dorta G, Keller W, Jornod P, Meuli R, Schnyder P. Performance of multidetector computed tomography colonography compared with conventional colonoscopy. Gut2002; 51:207 -211[Abstract/Free Full Text]
  19. Hara AK, Johnson CD, Reed JE, et al. Detection of colorectal polyps with CT colography: initial assessment of sensitivity and specificity. Radiology1997; 205:59 -65[Abstract/Free Full Text]
  20. Johnson CD, Toledano AY, Herman BA, et al. Computerized tomographic colonography: performance evaluation in a retrospective multicenter setting. Gastroenterology2003; 125:688 -695[Medline]
  21. Sosna J, Morrin MM, Kruskal JB, Lavin PT, Rosen MP, Raptopoulos V. CT colonography of colorectal polyps: a metaanalysis. AJR 2003;181:1593 -1598[Abstract/Free Full Text]
  22. Morrin MM, Farrell RJ, Keogan MT, Kruskal JB, Yam CS, Raptopoulos V. CT colonography: colonic distention improved by dual positioning but not intravenous glucagon. Eur Radiol2002; 12:525 -530[Medline]
  23. Yee J, Hung RK, Akerkar GA, Wall SD. The usefulness of glucagon hydrochloride for colonic distention in CT colonography. AJR 1999;173:169 -172[Abstract/Free Full Text]
  24. Svensson MH, Svensson E, Hellstrom M. Bowel wall visualisation at CT colonography. Acta Radiol2002; 43:87 -95[Medline]
  25. Yee J, Kumar NN, Hung RK, Akerkar GA, Kumar PR, Wall SD. Comparison of supine and prone scanning separately and in combination at CT colonography. Radiology2003; 226:653 -661[Abstract/Free Full Text]
  26. Gryspeerdt S, Lefere P, Dewyspelaere J, Baekelandt M, van Holsbeeck B. Optimisation of colon cleansing prior to computed tomographic colonography. JBRBTR 2002;85:289 -296
  27. Thomeer M, Carbone I, Bosmans H, et al. Stool tagging applied in thin-slice multidetector computed tomography colonography. J Comput Assist Tomogr 2003;27:132 -139[Medline]
  28. Pickhardt PJ, Choi JR, Hwang I, et al. Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults. N Engl J Med2003; 349:2191 -2200[Abstract/Free Full Text]
  29. Jurik AG, Jessen KA, Hansen J. Image quality and dose in computed tomography. Eur Radiol1997; 7:77 -81[Medline]
  30. Takahashi M, Maguire WM, Ashtari M, et al. Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique. Invest Radiol1998; 33:68 -73[Medline]
  31. Husstedt H, Prokop M, Becker H. Window width as a dosage-relevant factor in high-contrast structures in CT [in German]. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr1998; 168:139 -143[Medline]
  32. Bensen S, Mott LA, Dain B, Rothstein R, Baron J. The colonoscopic miss rate and true one-year recurrence of colorectal neoplastic polyps: Polyp Prevention Study Group. Am J Gastroenterol1999; 94:194 -199[Medline]
  33. Rex DK, Cutler CS, Lemmel GT, et al. Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies. Gastroenterology1997; 112:24 -28[Medline]
  34. Imperiale TF, Wagner DR, Lin CY, Larkin GN, Rogge JD, Ransohoff DF. Results of screening colonoscopy among persons 40 to 49 years of age. N Engl J Med2002; 346:1781 -1785[Abstract/Free Full Text]
  35. Villavicencio RT, Rex DK. Colonic adenomas: prevalence and incidence rates, growth rates, and miss rates at colonoscopy. Semin Gastrointest Dis 2000;11:185 -193[Medline]
  36. Edwards JT, Wood CJ, Mendelson RM, Forbes GM. Extracolonic findings at virtual colonoscopy: implications for screening programs. Am J Gastroenterol 2001;96:3009 -3012[Medline]
  37. Gluecker TM, Johnson CD, Wilson LA, et al. Extracolonic findings at CT colonography: evaluation of prevalence and cost in a screening population. Gastroenterology2003; 124:911 -916[Medline]
  38. Hara AK, Johnson CD, MacCarty RL, Welch TJ. Incidental extracolonic findings at CT colonography. Radiology2000; 215:353 -357[Abstract/Free Full Text]

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
J. Sosna, T. Sella, O. Sy, P. T. Lavin, R. Eliahou, S. Fraifeld, and E. Libson
Critical Analysis of the Performance of Double-Contrast Barium Enema for Detecting Colorectal Polyps >= 6 mm in the Era of CT Colonography
Am. J. Roentgenol., February 1, 2008; 190(2): 374 - 385.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. C. Lucey, J. C. Varghese, A. Hochberg, M. A. Blake, and J. A. Soto
CT-Guided Intervention with Low Radiation Dose: Feasibility and Experience
Am. J. Roentgenol., May 1, 2007; 188(5): 1187 - 1194.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
D. S. WERDERMAN
CT Colonography
Radiol. Technol., March 1, 2007; 78(4): 309CT - 324CT.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
T. Mang, A. Maier, C. Plank, C. Mueller-Mang, C. Herold, and W. Schima
Pitfalls in Multi-Detector Row CT Colonography: A Systematic Approach
RadioGraphics, March 1, 2007; 27(2): 431 - 454.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Figures Only
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohnen, M.
Right arrow Articles by Moedder, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohnen, M.
Right arrow Articles by Moedder, U.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS